Resetting to Factory Default Settings
If the camera no longer functions as expected, you can choose to reset the camera to its factory default settings.
Use the firmware revert button to reset the camera.
NOTE: Be careful not to scratch the dome bubble.
Figure 1: The firmware revert button.
1. Ensure the camera is powered on.
2. Remove the dome cover by loosening the screws that fix the cover to the base. The Torx key included
with the dome camera can be used to loosen the screws
3. Using a straightened paperclip or similar tool, gently press and hold the firmware revert button for two
seconds.
4. Re-install the dome cover.
CAUTION Do not apply excessive force. Inserting the tool too far will damage the device.