3. Insert the two power wires into the two terminals on the
power connector block. The connection can be made with
either polarity.
Use a small slotted (5/64” or 2 mm blade width)
screwdriver to loosen and tighten the terminals.
4. Attach the power connector block back into the receptacle
on the device.
When you select the wire used to provide power, be sure to select a
gauge that is heavy enough for the wiring distance. Refer to the
following table for the maximum wire length for different wire gauges.
Warning — This product is intended to be supplied by a UL
Listed Power Unit marked “Class 2” or “LPS” or “Limited
Power Source” with output rated 12 VDC or 24 VAC, 6 W
min. or PoE rated 48 VDC, 6 W min.
Table:Wire Length for Different Wire Gauges
Wire Gauge
Maximum Run Length
(ft [m])
AWG
mm
2
24 VAC 12 VDC
24 0.2 164[50] 43[13]
22 0.33 267[81] 71[21]
20 0.5 428[130] 114[34]
18 0.82 680[207] 181[55]
16 1.3 1071[326] 285[87]