EasyManuals Logo

AVIRE MEMCO Pana40 Plus User Manual

AVIRE MEMCO Pana40 Plus
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Pana40 Plus
2-in-1 & 3-in-1 Mechanical Edges
Installation Guide
INSTALLATION
Dynamic Installation
+ Position each detector 5mm above the sill
+ Ensure that the detectors are aligned level and straight with each other
+ Please refer to the lift/elevator OEM manual for the correct installation of the mechanical safety edges
+ Secure the cables with the P-clips and screws provided. Ensure there are no tight bends and the cables are not
stressed or stretched as the doors move
Ref No. 745 850 (ML) V01
Fig 1: Proles
Connect with 841 Controller
Pana40 Plus edges must be installed with an 841 Pana40 Plus Controller. Refer to the Controller Installation Guide for
details on conguration.
2in1 : 28mm prole
(745 050)
2in1: 20mm prole (755 200)
3in1: 20mm prole (775 200)
2in1: 22mm prole (755 220)
3in1: 22mm prole (775 220)
2in1: 25mm prole (755 260)
3in1: 25mm prole (775 260)
60 60 55 60
28
28
28
34
19
28
16
20
18
22 25
Memco is a brand of Avire
Avire Ltd
Unit 1, The Switchback
Gardner Road
Maidenhead
Berkshire
SL6 7RJ, UK
T: 01628 540100
F: 01628 621947
E: sales.uk@avire-global.com
W: www.memco-global.com
W: www.avire-global.com
P40+2in1&3in1 IG V01 (GB)_PA/07/12/2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AVIRE MEMCO Pana40 Plus and is the answer not in the manual?

AVIRE MEMCO Pana40 Plus Specifications

General IconGeneral
BrandAVIRE
ModelMEMCO Pana40 Plus
CategorySecurity Sensors
LanguageEnglish

Related product manuals