Operating Manual for Controller VIBTRONIC
®
SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 4–3
4
Controllers are temperature sensitive! Make certain that the units are not installed
near external heat sources, such as direct sunshine or radiators. The ambient tem-
perature must not exceed +50 °C during operation!
4.1.2 Cabinet Unit
The controllers are delivered in a closed housing (IP 55 acc. to EN 60529). The
cabinet unit is suitable for mounting to vertical walls or frames.
Carry out the installation as follows:
F
Screw the mounting plates (delivered loose) onto the housing as shown in
figure 4.2.
F
Use the hole pattern shown in figure 4.2 to drill the necessary holes for the
fastening screws.
F
Hand-fasten the mounting plates to a vibration-free vertical wall or frame.
Controllers are vibration sensitive! Do not install on vibrating components, and
under no circumstances to the vibration conveyor device itself!
Controllers are temperature sensitive! Make certain that the units are not installed
near external heat sources, such as direct sunshine or radiators. The ambient tem-
perature must not exceed +40 °C during operation!
4.2 Terminal Assignment
The following chapters explain the terminal assignment on the controllers as well
as the available options. Read these sections before you begin wiring, and observe
the information regarding electromagnetic compatibility!
4.2.1 Minimum Terminal Assignment
The minimum terminal assignment for operating a magnetic vibrator for voltage-
regulated mode and without external control input is shown in Figure 4.3.
Terminals 12 and 13 must be connected by a bridge. The bridge is mounted at the
factory.