- 10 -
GENERAL FEATURES
Outdoor self-powered sirens for security systems:
City LED Plus with small white ABS container
City X LED Plus with small STAINLESS Steel ABS container
City CARBON LED Plus with small ABS container with carbon look
TS85 P LED Plus with white ABS container
TS85 V LED Plus with white varnished Galvanized iron container
TS85 X LED Plus in AISI 304 STAINLESS Steel container
- The TS85 P/V/X LED Plus models internally have an independent fastening cover that creates a second obstacle
to possible tampering.
- The unied ant-removal system found on all models enables to simultaneously protect against the removal from the
wall and the opening of the cover and further simplies assembly operations.
GENERAL FEATURES
Initial blockage The battery can be connected in the absence of power from the control unit,
program and close the cover without activating the Cone. The siren does not
sound until the power supply terminals (+/-) and the control terminal (+SA)
are not connected to the control unit.
Emergency timer If the device that controls the siren is broken, a programmable emergency
timer blocks it
Type of sound modulation It is possible to select from one of the 8 different tones
Alarms Count If programmed, it counts a maximum of 5 alarms in 24 hours
FLASH mode If the SA input is unbalanced, it flashes for 40 minutes
If the SA input is unbalanced, it flashes until the STC input is rebalanced
If the SA input is unbalanced, it flashes until the SA input is rebalanced
Siren control input (STC) Programmable
Control input (LED) Programmable
Block (B) Input Blocking of the sound in the presence of a positive
FAILURE (FAULT) output Microprocessor block
Low level or missing battery
Flash fault
LED fault
Cone fault
Cone management circuit fault
TAMPER (T T) output Siren and/or cover anti-removal
Anti-vibration
Overheating
Anti-foam (optional S85 mode)
Battery polarity inversion The siren is protected against accidental battery polarity inversion
Current limiter All models have a current limiter to avoid the siren from overloading the control
unit.
Autotest FLASH, LED, Cone, Cone management Circuit, Battery periodic check
Level indicator A bubble, inserted inside the container, enables correct installation
AUTOTEST
All models have an autotest system for the following components:
LED test: performed periodically.
Cone management Circuit test: performed exclusively with siren in alarm state and integrated cone
Cone test: performed exclusively with idled siren
Battery "dynamic" test: within 15 minutes from the rst power supply or at the exit of the programming and, subsequently, at intervals
of approximately 24 hours, the LEDS and the Flash are activated simultaneously to verify the correct functioning of the battery.
Battery "static" test: a check of the tension value at the ends of the battery is performed periodically by disconnecting the charge
coming from the control unit.
Once all connections and programming are completed and the siren is closed, perform a test of the alarm to test correct
functioning.
The power supply must come from a very low voltage security circuit with the features of a limited power source protected
by a fuse.