This product cannot be used without an external panel for protection against contact. Panels are sold separately.
Carefully read this manual before unpacking, installing, and using the ventilator to avoid damage.
Symbols indicate technical safety warnings to avoid injury and danger. Obey all precautions.
This product cannot be used without an external panel for protection against contact. Panels are sold separately.
Carefully read this manual before unpacking, installing, and using the ventilator to avoid damage.
Symbols indicate technical safety warnings to avoid injury and danger. Obey all precautions.
Use, connection, and exploitation are subject to special regulations and common safety standards.
Comply with safety precautions, domestic regulations, and prevent contact with rotating parts.
Ensure sufficient air intake for furnaces and obey local acts. Installation by trained specialists is required.
Device cannot be operated by people with psychological/mental/motor disorders or lack of experience.
Check structural elements for carrying capacity before installation to prevent damage or endangerment.
People with disabilities or lack of experience can only operate under supervision or after training.
Improper use or installation by untrained staff can lead to danger.
Designed for normal air or air with little dust, aggression, and humidity in moderate atmospheres.
Permitted only as permanent installation on internal walls, max 40°C, IPX4 class II in humid rooms.
Cannot be used with viscous, corrosive, or flammable mix contamination.
The device is equipped with ball bearings and has a minimum 30,000-hour lifespan.
Do not use the ventilators in an explosive environment.
Prevent extreme operation with frequent starts and stops.
The ventilators can be used with a thyristor rotation regulator.
Standard models with blocks are installed according to diagram Fig. 1. Turns on with light or switch.
Models with pull switches installed per Fig. 1. Pull switch used to turn ventilator on/off.
Models with timers (delayed shutdown) installed per Fig. 2. Adjustable delay up to 30 minutes.
Detects humidity (40%-90%) and operates automatically with timer. Attention: manual override for humidity extremes.
Features speed regulation processor. Adjusted with sensory keys and signalled by LEDs.
Ventilator works at four speeds, indicated by LEDs. Two delayed shutdown modes: minute and hour.
Device can be installed, connected, and started only by trained staff according to regulations.
Fan housing requires front panel protection. Users must preserve effective standards for adequate protection.
Remove foreign objects from interior and check if rotor moves freely before installing.
Connection by authorized electricians only. Follow standards, safety regulations, and provider conditions.
Lead cable carefully, check sealing, use additional sealing if needed, and secure cable to prevent water penetration.
Check for vibrations, noise, power uptake, and smooth operation after starting. Ensure air flows properly.
Determine installation spot precisely. Dimensions are on technical diagrams on product's packaging.
Remove cover, lead cable, push housing into hole, fix with screws, and reattach head and cover.
Remove screws to access the control panel for wiring connections.
Set time delay and humidity sensor with a tool for versions T and H.
Operating maintenance and cleaning should be performed by specially trained professionals.
Disconnect power before work, obey safety standards, and never perform maintenance on an operating ventilator.
Air ducts must be free from foreign objects; throwing objects through is dangerous.
Motor has 'lifespan lubrication'; bearing replacement needed when lubricant runs out. Contact manufacturer for issues.
Disconnect power before cleaning. Avoid aggressive agents, jet cleaners, or water streams near motor.
Clean with damp cloth, ensure no liquid enters motor. Run for 2 hours at high speed to dry.
Inspect ventilator annually, mechanical/electrical connections quarterly, and device on any defective operation.
The grating on the ventilator mouth must be kept clean.
5-year warranty from purchase date, effective with proof of purchase (bill, invoice).
Warranty covers flaws and damage caused by the manufacturer. Damaged device must be delivered for repair.
Excludes damage from improper installation, unauthorized individuals, misuse, improper transport/storage, lawless repairs, mechanical damage.
Effective operation and warranty conditioned by periodical maintenance performed at least twice a year by authorized individuals.