C. Ceiling mount or side mount: (Note: The mounting brackets are available to purchase.)
3.3.1 Ceiling mount - mount the threaded rods
securely to the studs in the ceiling.
3.3.2 Securely mount the mounting brackets
and the mounting plate. Please put
mounting plate for ceiling mount.
3.3.3 Side mount – mount to the top door
frame securely.
3.3.4 Securely mount the mounting brackets
and the mounting plate.
Note: This air curtain should be installed indoor, should not have moisture, water, rain, or
snow reachable. Consult with your electrical professional for 120V electrical hard wiring.
WARNING: Make sure the air curtain is securely mounted on the wall; otherwise, the air
curtain may fall and injury to persons.
4. TECHNICAL PARAMETER
Model
No.
entry
opening
Voltage
(V~Hz)
Power
(W)
Current
(A)
Max air
velocity
(FPM)
(CFM)
Noise level
(dB)
Net
weight
(Lb)
H L H L
FM-1209T
38
120V,
60Hz
140
1.46
2165 (H),
1772 (L)
1112 874 57 55 22.0
Note: The data are subjected to change without notice due to product development.