Appendix B: The Parameter List AXIS 200+ Users Manual
72
Camera specific
parameters
LOGO_X. = 10
Axis logo position in pixels, the horizontal coordinate.
LOGO_Y. = 10
Axis logo position in pixels, the vertical coordinate.
LOGO_SHOWN. = NO
Enables Axis logo display.
CLOCK_X. = 1
Clock position in pixels, the horizontal coordinate.
CLOCK_Y. = 1
Clock position in pixels, the vertical coordinate.
CLOCK_SHOWN. = NO
Enables clock display.
CLOCK_MODE. = AM/PM
AM/PM or 24 hours time format.
Image appearance
parameters
COMPRESSION. = MEDIUM
Determines snapshot compression and consequently file size.
BRIGHTNESS. = 5
Brightness control.
COLOR. = LEVEL
Color control.
WHITE_BALANCE. = AUTOMATIC
Control the white balance settings.
CONTRAST. = 5
Not used in AXIS 200+.
LIGHT_FRONT_LED. = YES
Enables Snapshot indicator.
ROTATION. = NORMAL
Snapshots can have varied orientation.
MIRROR. = NO
Enables mirroring of image from right to left.
CACHE_TIME. = 0
Determines maximum cache period for snapshots,
e.g the same snapshot will displayed for all requests within a 3
seconds period.
AUTOADAPT_PERIOD. = 0
Period for automatically adjusting the image settings. Set within
the Image Wizard.
SHARPNESS. = 166
Image sharpness.
SHUTTER_SPEED. = 1/50
Shutter speed.
AE_MODE. = AUTO
Exposure mode. If set to Auto, the shutter speed and gain will be
controlled automatically.
AGC_GAIN. = 16dB
Image gain.
System Parameters
MODEM_TYPE. =
Autodetect Modem or Null Modem.
SERIAL_MODE. = DISABLED
Enables serial mode for ppp or zmodem access when set to
Full_Support, Inbound Only or Outbound Only. Enables
input/output operation via a TCP client application when set to
TCP_input_output.
SERIAL_BAUD. = 9600
Baud rate.
SERIAL_FLOW. =
Modem server operation mode. Set to Hardware (RTS/CTS).
MODEM_INIT. =
String of commands to be sent to the modem for setup. Used for
non-US Robotics modems.
BUSY_REDIAL. = 0
Specifies how many additional attempts the AXIS 200+ will make
to establish a connection in case the line is busy.
Parameter name Value Description