1ª 10155 ES 9 - 2009
52
Module affected: POWER SUPPLY
SYMPTOMS
x Nothing works.
FAULTY ELEMENT
- Mains of 220 v.
- Fusible of 1Amp.
- Main switch off (Must be lit).
x Blows the Fuse. - Short circuit.
- Transformer.
x Shocks on touching machine. - Earth.
- Filter.
Module affected: ILLUMINATION
SYMPTOMS
x No illumination.
FAULTY ELEMENT
- Fluorescent.
- Starter.
- Transformer.
- Loom illumination.
Module affected: CONTROL BOARD MACHINE
SYMPTOMS
x The LED diode of the control board is
flashing.
FAULTY ELEMENT
- Control board.