EasyManua.ls Logo

B. Braun Acculan 3Ti GA677 - User Manual

B. Braun Acculan 3Ti GA677
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Aesculap Power Systems
Acculan® 3Ti
Instructions for use
Acculan® 3Ti charger GA677
Gebrauchsanweisung
Acculan® 3Ti Ladegerät GA677
Mode d’emploi
Chargeur Acculan® 3Ti GA677
Instrucciones de manejo
Cargador Acculan® 3Ti GA677
Istruzioni per l’uso
Caricabatterie Acculan® 3Ti GA677
Instruções de utilização
Carregador Acculan® 3Ti GA677
Gebruiksaanwijzing
Acculan® 3Ti lader GA677
Brugsanvisning
Acculan® 3Ti opladningsapparat GA677
Bruksanvisning
Acculan® 3Ti laddningsaggregat GA677
Инструкция по примению
Зарядное устройство Acculan® 3Ti GA677

Table of Contents

Questions and Answers

Summary

Safe handling

Product description

General description of the product.

System components

Lists the parts that make up the system.

Components necessary for use

Lists essential components required for operation.

Intended use

Operating principle

Details how the charger functions and operates.

Charging principle

Explains the method used for charging the batteries.

Battery temperature

Charging time

Discusses factors influencing charging duration and its monitoring.

Preparation and setup

Working with the Acculan 3 Ti charger

System set-up

Steps to set up the charging system.

Connecting the power supply

Details on how to connect the charger to the power source.

Function checks

Procedures for verifying the charger's functionality.

Operation

Charging Acculan 3 Ti rechargeable batteries GA666 and GA676

Charging progress indicator

Explains the charging progress indicator for this battery type.

Battery change recommended indicator

Explains the indicator for recommended battery replacement.

Action request indicator

Explains the action request indicator for this battery type.

Charging Acculan rechargeable batteries GA646, GA626 and GA616

Charging progress indicator

Explains the charging progress indicator for this battery type.

Action request indicator

Explains the action request indicator for this battery type.

Processing

Cleaning;Disinfecting

Servicing;Inspection

Troubleshooting list

Product not functioning at all

Addresses issues where the product is completely non-functional.

Battery is not charged

Solves problems related to batteries not charging.

Changing fuses

Technical Service

Accessories;Spare parts

Mains power cord

Details about the power cord, including specifications and part numbers.

Spare parts

Lists specific spare parts like fuse sets and charging bays.

Technical specifications

Mains power ranges

Voltage and current ranges for mains power connection.

AC frequency

Operating frequency for alternating current.

Protection class

Device's protection class against electrical hazards.

Charging;Output voltage

Voltage levels during charging and output.

Device fuse

Specifications for the device's fuse.

Classification acc. to directive 93;42;EEC

Classification according to medical device directive.

EMC

Electromagnetic compatibility standards.

Norms

Applicable technical norms and standards.

Disposal

Changing a charging bay

Distributor in the US;Contact in Canada for product information and complaints

B. Braun Acculan 3Ti GA677 Specifications

General IconGeneral
Input Voltage100-240 V AC
Input Frequency50/60 Hz
Battery TypeLithium-ion
Operating Temperature10°C to 40°C
Storage Temperature-10°C to +50°C
Relative Humidity30% to 75%