Model BPE600-127V
BPE600-240V
Input Data (DC)
Operation Voltage Range 20V-55V
Startup Voltage
20V
Maximum DC Short Circuit Current
Output Data (AC)
Nominal Output Voltage 127/240V
Nominal Output Current
2.5A/4A
Default/Protect Output Voltage Range
184-265V
Extended/Reconnect Output Voltage Range
95-155V
184-265V
Nominal Output Frequency
Extended/Reconnect Output Frequency Range
50Hz/45-55,60Hz/59.3-60.5
Total Harmonic Distortion <3%
Efficiency
Night Power Consumption 50mW
Mechanical Data
Storage Temperature Range
-40 °C to +85 °C
Weight 2.2kg
Enclosure Rating IP65
Wet Locations Classification For Wet Locations
Relative Humidity Ratings
0-95%
Certificates UL1741,VDE0126,VDE4105,IEC62109,CE
© All Rights Reserved
Pollution Degree Classification PD3
Powerline
Operating Ambient Temperature Range -40 °C to +65 °C
Max. Inverter Efficiency 96.5%
Default/Protect Output Frequency Range
50Hz/45-55,60Hz/59.3-60.5
Maximum Output Power 600W
Maximum Input Voltage 60V
BPE600 Microinverter Datasheet
MPPT Voltage Range 25V-55V
Maximum Input Current
10.4A x 2
187mm X 163mm X 29mm
Natural Convection - No Fans
Maximum Altitude Rating
All Data At This Technical Specifications Has Been Tested Under <2000m
50Hz/60Hz Auto Sense
13A
95-155V