EasyManua.ls Logo

Bagela BA 10000 - User Manual

Default Icon
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
B
B
®
®
B
B
Bagela Baumaschinen GmbH&Co
Gottlieb-Daimler-Str. 5
24568 Kaltenkirchen
Tel: +49 (0) 4191 99330
Fax:+49 (0) 4191 993399
e-mail: info@bagela.de
GERMANY
Gülzer Straße 6
19258 Boizenburg
Tel: +49 (0) 38847 4080
Fax: +49 (0) 38847 40818
e-mail: export@bagela.de
GERMANY
Bagela
Operating instructions
Spare part list
Asphaltrecycler
BA 10000

Questions and Answers

  • R
    rodriguezanthonyAug 18, 2025
    What to do if Bagela BA 10000 Construction Equipment burner is on, flame is on, but goes out again and malfunction lamp burns?
    • B
      Brandon WillisAug 18, 2025
      If the burner ignites but the flame goes out and the malfunction lamp illuminates, it could be due to a defective photosensor, so check the connection of the photosensor and replace it if necessary. The burner head adjustment may be incorrect, so check the basic settings. Alternatively, the oil firing control might be defective, so replace it.
  • D
    Darren WilliamsAug 28, 2025
    What to do if the motor of Bagela BA 10000 Construction Equipment burner does not turn?
    • D
      Donald NixonAug 28, 2025
      If the burner motor doesn't turn, the cause may be that there is no power supply. To solve this, check the power supply and operate the overload switch at the generator.
  • S
    scott09Nov 8, 2025
    What to do if Bagela BA 10000 Construction Equipment burner is on but there is no flame and the malfunction lamp is on?
    • B
      bduranNov 8, 2025
      If the burner is on, but there is no flame and the malfunction lamp is lit, several issues could be the cause. It could be that the filter is blocked, so replace the filter cartridge and clean the filter strainer. The pump may be drawing in air, so fill the fuel oil tank, replace the O-rings, check the suction line for leaks, and shut the vent cock. The photosensor might be getting outside light, so push the photosensor into the bushing, ensuring the glass side faces the tumbler. A blocked nozzle could also be the cause, so replace the nozzle. Check the transformer, cables, and ignition electrodes and replace the ignition electrodes if there is no ignition spark. Also, check the plug for proper seating and replace the solenoid valve if it is defective. Verify the generator voltage is at 23...

Summary

Safety Instructions for Asphalt Recyclers

Operating Instruction - Short Version

Procedure for Reprocessing Broken-up Asphalt Slabs

Set-up of Recycler for Stationary Operation

Securing the recycler, leveling, and positioning for stationary use.

Start-up

Steps for starting the engine and engaging the tumbler.

Burner Operation

Guidance on operating the burner in stages and setting temperature.

Procedure for Reprocessing Milling Asphalt (Asphalt Fines)

Setting up of the Recycler

Leveling the recycler with a slight upward tilt for discharge.

Charging

Instructions for charging dry asphalt fines and monitoring pressure.

Discharging

Procedure for continuous discharge and temperature adjustment.

Troubleshooting Diagram for Light Oil Burner

Maintenance Instructions

Burner Components and Their Function

Components

Maintenance of the Oil Burner

Pump Operating Principle

Hydraulic Diagram

Electric Diagram

Bagela BA 10000 Specifications

General IconGeneral
BrandBagela
ModelBA 10000
CategoryConstruction Equipment
LanguageEnglish