  • F
    fergusonkevinAug 13, 2025
    What to do if Bagela BA 7000F burner is on, flame is on, but goes out again and malfunction lamp burns?
    • W
      Wayne RomeroAug 14, 2025
      If the burner ignites but the flame goes out and the malfunction lamp illuminates, it could be due to a defective photosensor, so check the connection of the photosensor and replace it if necessary. The burner head adjustment may be incorrect, so check the basic settings. Alternatively, the oil firing control might be defective, so replace it.
  • J
    Jeffrey SmithAug 22, 2025
    What to do if the motor of Bagela BA 7000F burner does not turn?
    • C
      Connie HughesAug 23, 2025
      If the burner motor doesn't turn, the cause may be that there is no power supply. To solve this, check the power supply and operate the overload switch at the generator.
  • R
    Ronald LopezNov 3, 2025
    What to do if Bagela Construction Equipment burner is on but there is no flame and the malfunction lamp is on?
    • B
      Bridget GreenNov 3, 2025
      If the burner is on, but there is no flame and the malfunction lamp is lit, several issues could be the cause. It could be that the filter is blocked, so replace the filter cartridge and clean the filter strainer. The pump may be drawing in air, so fill the fuel oil tank, replace the O-rings, check the suction line for leaks, and shut the vent cock. The photosensor might be getting outside light, so push the photosensor into the bushing, ensuring the glass side faces the tumbler. A blocked nozzle could also be the cause, so replace the nozzle. Check the transformer, cables, and ignition electrodes and replace the ignition electrodes if there is no ignition spark. Also, check the plug for proper seating and replace the solenoid valve if it is defective. Verify the generator voltage is at 23...

Summary

Safety Instructions for Asphalt Recyclers

Operating Instructions (Short Version)

General Description

Procedure for Reprocessing Broken-up Asphalt Slabs

Set-up of Recycler for Stationary Operation

Steps to set up the recycler for stationary use, including securing and leveling.

Start-up

Procedures for starting the engine and engaging the tumbler drive.

Charging

How to fill the recycler with asphalt, noting the hydraulic pressure gauge.

Burner Operation

Steps for operating the burner, including stage settings and thermostat.

Discharging

Process for discharging reprocessed asphalt, including timing and continuous operation.

Work Interruption

Guidelines for interrupting work, covering short and long breaks.

Drum Cleaning

Steps for cleaning the drum after operation, including gate operation.

Procedure for Reprocessing Milling Asphalt (Asphalt Fines)

Setting up of the Recycler

How to level the recycler for reprocessing milling asphalt, with a specific angle.

Charging

Instructions for charging asphalt fines, emphasizing dry storage and pressure levels.

Discharging

How to discharge reprocessed fines, adjusting gate and discharge end based on temperature.

Troubleshooting Diagram for Light Oil Burner

Maintenance Instructions

Attachment

EC-Declaration of Conformity

Official declaration confirming compliance with EU directives for the machine.

Technical Data

Specifications of the BA 10000 model, including engine, output, and dimensions.

Two-Stage-Oil-Burner

Detailed information on the specific two-stage oil burner used in the asphalt recycler.

Hydraulic Diagram

Schematic representation of the machine's hydraulic system layout.

Electric Diagram

Wiring diagram illustrating the electrical connections and components.

Lighting System

Details of the 12V lighting system for the machine.

Bagela BA 7000F Specifications

General IconGeneral
BrandBagela
ModelBA 7000F
CategoryConstruction Equipment
LanguageEnglish

Related product manuals