When
the
unit
is
operating,
the
viewscreen
must
be
open
exactly 8",
or
must
be
completely
closed.
At
any
other
setting,
the
sash
level a
lam1
indicator
will
flash.
2-
Blower
On/Off
Switch-
This
switch
controls
the
power
to
the
blower
for
the unit.
When
the
switch
is
turned
on,
the
yellow
indicator
will
light. The lights
and
outlets
will
not
operate
unless
the
blower
switch
is
turned
on
first.
The
indicator
light
above
the
switch
shows
that
the
switch
has
been
turned
on.
3-
Outlet
On/Off-
This
switch
controls
the
two
outlets
on
each
side
of
the
work
area.
When
the
outlets
are
turned
on,
the
yellow
indicator
above
the
switch
will light.
The
indicator
above
the
switch will
light
when
the
outlets
are
turned
on.
4-
Light
On/Off
Switch-
This
switch
controls
the
fluorescent light
inside
the
work
area.
The
blower
must
be
turned
on
first.
The
fluorescent
light
will
not
operate
if
the
UV
light
is
already
htrr
ed
on.
The
indicator
above
the
switch
will
light
when
the
fluorescent
light
is
turned
on.
5-
Ultraviolet
(Germicidal) Light
On/Off
Switch
A
bulb
which
produces
light
in
the
ultraviolet
range
(UV)
may
be
used
to
help
disinfect
the
work
area.
This
switch
controls
the
UV
light
inside
the
work
area. Before
the
UV light
may
be
turrted on, the
blower
n1ust be turned on, the
viewscreen
must
be
fully closed,
and
the
t1uorescent light
must
be
turned
off.
The
UV light
will
shut
off
if
the
view
screen is
opened.
The
indicator
above
the
switch
will light
when
the
UV
light
is
turned
on.
Air
Pressure
Monitor
The
air
pressure
monitor
is
mounted
on
the
left
side
of
the
control
panel
(comes
standard
on
SGII
ULTRA
model
and
as
an
option
on
the
SGII
3tandard
model).
See Fig.
5.
The
bar
graph
12
shows
the relative cabinet
perfonnance,
measured
in
terms
of
the total
volume
of
air
being
handled
bv
the unit.
The top
of
the
lighted
area indicates
the
relative
airflow.
When
the
airtlow
is
normal,
the
LEUs
in
the
center
of
the
bar
graph
will glow
with
a
steady
green
light.
If
just
one
or
two
LED's
at
the
bottom
of
the
graph
glow
with
a
red
light,
the
milt
is
handling
a
low
volume
of air.
An
alarm
will
also
sound.
This
indication
mea11s
that
the
unit
is
not
receiving
enough
intake
air.
.··
vV..4RNING!
If
the
unit
continues
to
operate
in
this
condition,
it
is
possible
that
contamination
may
spread
outside
of
the
work
area. The
product
inside
the
work
area
may
also
be
cmttil1n.ina.ted.
If
you
see
the-
lo1.V
airflow
indicator,
take
these steps:
Lea<?e
the
unit
running. The.
blower
will
continue
to
move
air
through
the
cabinet
and
filters.
Close
the
window
completely.
Call
a
supervisor
and!
or
a
servtce
·
·.
techttician.
lf
the
two
LED's
at
the
top blink
with
a
green
light, this indicates a
high
air
flow
condition.
If
the
sash
is
lowered
and
the
UV light is
on,
this
is
a
safe condition.
However,
ii
you
are
working
in
the
cabinet
or
the
sash
is
at
the
operating
height
(8"), check
the
intake
grilles for blockage.
If
this
condition
persists, call a
supervisor
or
main-
tenance
technician.
Product
protection
may
be
compromised.
Magnehelic
Gauge
Your
SteriJCARD"'JI
mav
be
equipped
with
a
magnehelic
gauge
in
place
of
the air
pressure
monitor
(all SCI!
Standard
models
feature
the
rnagnehelic gauge). The magnehelic
gauge
should
be zeroed after
the
unit
has been
leveled,
and
before
it
is
injtiallv
turned
on.

Related product manuals