53857_02-97_A
DIP Switches Definitions
WARNING:
Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this hot sheet.
DIP Switchbank A Key
A1 ............Test Mode (normally Off)
A2 and A3..........Control amp draw requirements. See Table 1
A4* ............In “ON” position, displays time in 24 hours (military\European time)
............In “OFF” position, displays 12 hour time
A5* ............In “ON” position, displays temperature in Celsius
............In “OFF” position, displays temperature in Fahrenheit
* Sets default for user preferences - only applies when persistent memory is reset (A12 On)
during power-up
A6 ............In “ON” position, Equipment timeout 30 minutes (4 hours for Pump 1 Low)
............In “OFF” position, Equipment timeout 15 minutes (2 hours for Pump 1 Low)
A7 ............In “ON” position, Cleanup Cycle – 30 minutes after spa use/timeout, Pump 1 Low & Ozone run for 1 hour
............In “OFF” position, NO Cleanup Cycle
A8
...........
In “ON” position, Ozone suppressed for 1 hour after pump or blower button press
...........In “OFF” position, NO Ozone suppression
A9 and A10.........Circ Pump Behavior settings. See Table 2
A11 ............In “ON” position (non-circ mode operation) Pump 1 is two-speed, Ozone is ON
in Filter & Cleanup Cycles only (in any circ mode), Pump 1 is one-speed,
Ozone is ON with Circ Pump
............In “OFF” position (non-circ mode operation) Pump 1 is two-speed, Ozone is
ON with Pump 1 Low
(in any circ mode) Pump 1 is two-speed, Ozone is ON with Circ Pump
A12 ............Persistent Memory Reset (used when the spa is powering up)
DIP Switchbank B Key
B1 ...........In “ON” position, single-speed Pump 2
...........In “OFF” position, two-speed Pump 2
B2 and B3..........Blower Speeds. See Table 3
B4 and B8
.........Fiber Optic and Color wheel control; Spa Light Enable
Note: The Light button on an ML900 panel is a SpaLight button.
The Light button on most other panels is an EitherLight button.
B5 ............Pump 4 enable when On. Jets 4 replaces Blower on Aux panel
B6 ...........In “ON” position, Alternate Panel layout
(ML900 scrunching enabled; ML550 and ML700
Jets 3 replaces Blower)
...........In “OFF” position, Normal Panel layout
B7 ...........In “ON” position, Spa Light operation is On/Off
...........In “OFF” position, Spa Light operation is dimmable
B9 ...........In “ON” position, single-speed Pump 3
...........In “OFF” position, two-speed Pump 3
B10 ...........In “ON” position, Pump 3 enabled (Jets 3 replaces
Light button on Aux panel)
...........In “OFF” position, Pump 3 disabled
B11 ...........In “ON” position, Mister enabled
...........In “OFF” position, Mister disabled
B12 ...........In “ON” position, Mister or Option replaces Blower button on Aux panels
...........In “OFF” position, no button replacement on Aux panels
Table 1 # of Hi-Speed
Pumps/Blower
Before Heat Disabled
A2 A3
OFF OFF 0
ON OFF 1
OFF ON 2
ON ON Up to 4
Table 2 Circ Pump
A9 A10 Behavior
OFF OFF No Circ Pum
p
ON OFF 24 Hr
OFF ON 24 Hr w/3°F Shut-Off
ON ON Acts like Pump 1 Low
(Filter Cycles, Polls)
Table 3
B2 B3 Blower Speeds
OFF OFF 0 (No Blower)
ON OFF 1 (on/off)
OFF ON 2
ON ON 3
B4 OFF
B4 ON
B8 OFF B8 ON
No separately-controlled fiber light; spa light enabled on both
SpaLight and EitherLight buttons; fiber light (not wheel) comes on
with spa light (at any intensity)
No separately-controlled spa
light; fiber light enabled on
both FiberLight and EitherLight
buttons; spa light comes on with
fiber light
Spa light and fiber light each
separately controlled; fiber light
enabled on both FiberLight and
EitherLight buttons; spa light
enabled on SpaLight buttons only