Quick Start Guide
MN1925 8/03
IMPORTANT NOTE !
This Quick Start Guide is not intended as a replacement for the full installation manual,
MN1919 MicroFlex Installation Manual, which provides detailed information about the MicroFlex.
The installation manual is available in PDF format on the supplied Baldor Motion T oolkit CD.
Mounting
MicroFlex is designed to be supported by four M5 screws, spaced
as shown in the diagram.
MicroFlex must be fixed to a smooth vertical metal surface to
ensure effective cooling.
63.5mm
167.7 mm
PrintedinUK
© Baldor UK Ltd
Baldor Electric Company
P.O. Box 2400
Ft. Smith, AR 72902-2400
U.S.A.
Visit www.supportme.net for the latest documentation and software releases.
Mounting
hole centers
Cooling for 6A & 9A models
Effective cooling for the MicroFlex is essential:
* The 3A model requires no additional cooling.
* The 6A model requires additional forced air cooling at 1.0m/s or greater.
* The 9A model requires additional forced air cooling at 2.5m/s or greater.
2
1
Heatsink
Fan
Quoted air velocities are for air originating from below the MicroFlex,
passing parallel to the heatsink. With MicroFlex mounted as specified,
quoted air velocities allow full drive rated current at ambient
temperatures up to 45°C.

Other manuals for Baldor MicroFlex

Question and Answer IconNeed help?

Do you have a question about the Baldor MicroFlex and is the answer not in the manual?

Baldor MicroFlex Specifications

General IconGeneral
Frequency50/60 Hz
SeriesMicroFlex
Control ModesTorque, Velocity, Position
CommunicationRS-232, RS-485
FeedbackResolver, Encoder
Protection FeaturesOvercurrent, Overvoltage, Overtemperature, Short Circuit
Operating Temperature0°C to 40°C
Humidity5% to 85% non-condensing
DimensionsVaries by model
WeightVaries by model

Summary

Mounting the MicroFlex Drive

MicroFlex Cooling Requirements

AC Power Supply, Fuses, and Filtering

Optional Regeneration Resistor

MicroFlex Motor Output Connections

24 VDC Control Supply and Filtering

Serial Communication Setup

Motor Feedback Input Configuration

Optional Step and Direction Inputs

Optional Analog Demand Input

Drive Enable Input Control