Balluff Network Interface Profinet, BNI PNT-502-105-Z015
www.balluff.com
7
3 Getting Started
I/O-Port
M12, A-coded, female
Pin
Function
1
+24V, 200mA
2
Input / Output
3
GND
4
Input / Output
5
FE
Note!
For the digital sensor inputs follow the input guideline per EN61131-2, type 2.
Note!
Each output serves a maximum current of 2,0 amperes. The IO-Link Ports only
1,6 A. Total current of the module has to be lower than 4 amperes per Pin.
Note!
Unused I/O port socket must be fitted with cover caps to ensure IP67 protection
rating.
IO Link-Port
M12, A-coded, female
Pin
Function
1
+24V, 1,6 A
2
Input / Output
3
GND
4
IO-Link / Input / Output
5
n.c.