Loading...
Edizione / Edition / Edition
Ediciòn / Ausgabe
2003/06
Cod. 0006080601
- Istruzioni per bruciatori modello
- Instruction for burners model
- Instrucciónes para quemadores modelos
- Mode d’emploi bruleûr
- Betriebsanleitung
BGN 40 P
BGN 60 P
BGN 100 P
BGN 120 P
BGN 150 P
BGN 200 P
BGN 250 P
BGN 300 P
BGN 350 P
it
sp
fr
de
Prima di iniziare a usare il bruciatore leggere
attentamente quanto esposto nel capitolo
“AVVERTENZE PER L’UTENTE, PER L’USO IN
SICUREZZA DEL BRUCIATORE” presente
all’interno del manuale istruzioni, che costituisce
parte integrante ed essenziale del prodotto.
en
Question and Answer IconNeed help?

Do you have a question about the baltur BGN 60 P and is the answer not in the manual?

Summary

Application of the Burner to Boiler

Gas Feed System at Low Pressure

Details on low-pressure gas feed systems and essential accessories.

Connecting Multiple Burners to Gas Network

Description of Operations

Explains the step-by-step operational sequence of the burner during startup and running.

Two-Stage Gas Burner Schematic Diagram

Starting Up and Regulation with Methane Gas

Guide for initial startup and operational adjustments for methane gas.

Instructions of Functioning

Combined Gas Valve (Monobloc) DUNGS

Adjustment Instructions

Procedures for adjusting the gas valve's initial release and pressure.

First Position Adjustment (1 st Flame)

Steps to adjust gas flow for the first flame stage.

Second Position Adjustment (2 nd Flame)

Steps to adjust gas flow for the second flame stage.

Setting DUNGS Gas Valves mod. ZRDLE

Setting Gas Flow for the 1 st Flame

Steps to set the gas flow rate for the first flame.

Setting Gas Flow for the 2 nd Flame

Steps to set the gas flow rate for the second flame.

Setting DUNGS Gas Valves mod. MVD and MVDLE

Setting the Initial Rapid Release Trip

Procedure to adjust the initial rapid release trip for MVD valves.

Setting Maximum Gas Flow

Steps to adjust the maximum gas flow rate for MVD valves.

Setting LANDIS & GYR Single Stage Gas Valves (SKP 10.110 B27 - SKP 10.111 B27)

Setting LANDIS & GYR Two Stage Gas Valves (SKP 10.123 A27)

Honeywell Gas Valves Type VE 4000 A1

Honeywell Gas Valves Type VE 4000 B1

Adjustment to the Flow

Procedure for adjusting the flow rate on VE 4000B1 gas valves.

Control Box for LFL 1... Series 02 Gas Burners

Control Program in the Event of Stopping

Explains stop indications and fault types for the control program.

Stop Indications

Details on the programmer's stop indications and sequence types.

LDU 11 Gas Valve Tightness Control Equipment

Notes on Use of Propane (L.P.G.)

Two-Stage Gas Burners: Troubleshooting Guide