EasyManua.ls Logo

Banner XS26-2 Series - Page 17

Banner XS26-2 Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XS2so and XS4so Solid-State Safety Output Modules
Solid State Safety Outputs
XS2so: 0.75 A max. at 24 V dc (1.0 V dc max drop)
XS4so: 0.5 A max. at 24 V dc (1.0 V dc max drop)
Inrush: 2 A max.
Output Off threshold: 1.7 V dc typical (2.0 V dc max.)
Output leakage current: 50 μA max. with open 0 V
Load: 0.1 μF max., 1 H max., 10 Ω max. per lead
Safety Ratings
PFH [1/h]: 5.8 × 10
-10
Proof Test Interval: 20 years
Certifications
Programmable
Safety
Controller
3NBN
External Power
XS2so: 24 V dc ± 20% (including ripple); 0.075 A no load, 3.075 A max. load
XS4so: 24 V dc ± 20% (including ripple); 0.1 A no load, 4.1 A max. load
Maximum Power-up Delay: 5 seconds after the Base Controller
Limited Isolation: ±30 V dc max. referenced to 0 V on the Base Controller
Bus Power
0.02 A
Test Pulse
Width: 200 μs max.
Rate: 200 ms typical
Output Protection
All solid-state outputs (safety and non-safety) are protected from shorts to 0 V
or +24 V, including overcurrent conditions
XS8si and XS16si Safety Input Modules
Convertible I/O
Sourcing current: 80 mA maximum at 55 °C (131 °F) operating
ambient temperature (overcurrent protected)
Bus Power
XS8si: 0.07 A no load, 0.23 A max. load
XS16si: 0.09 A no load, 0.41 A max. load
Safety Ratings
PFH [1/h]: 4 × 10
-10
Proof Test Interval: 20 years
Certifications
Programmable
Safety
Controller
3NBN
Safety Inputs (and Convertible I/O when used as inputs)
Input On threshold: > 15 V dc (guaranteed on), 30 V dc max.
Input Off threshold: < 5 V dc and < 2 mA, –3 V dc min.
Input On current: 5 mA typical at 24 V dc, 50 mA peak contact cleaning current
at 24 V dc
Input lead resistance: 300 Ω max. (150 Ω per lead)
Input requirements for a 4-wire Safety Mat:
· Max. capacity between plates: 0.22 μF
· Max. capacity between bottom plate and ground: 0.22 μF
· Max. resistance between the 2 input terminals of one plate: 20 Ω
Output Protection
The convertible inputs are protected from shorts to 0 V or +24 V, including
overcurrent conditions
XS/SC26-2 and SC10-2 Safety Controllers
www.bannerengineering.com - Tel: + 1 888 373 6767 17

Table of Contents

Related product manuals