Mute Function
Two Way - 1 Sensor Pair
M0:SO1
M0:OS1
M0:MSP1
M0:ME1
On or Off
Figure 74. Timing Diagram—Two-Way Muting Block, One Muting Sensor Pair
Mute Function
Two Way - 2 Sensor Pair
Max.
Time
Max.
Time
Max.
T
ime
Max.
Time
< 3s< 3s
< 3s< 3s
M0:MSP2-1
M0:MSP2-2
Mute Time Limit
M0:SO1
M0:OS1
M0:ME1
M0:MSP1-1
M0:MSP1-2
On or Off On or Off
Figure 75. Timing Diagram—Two-Way Muting Block, Two Muting Sensor Pairs
XS/SC26-2 and SC10-2 Safety Controllers
www.bannerengineering.com - Tel: + 1 888 373 6767 91