Do you have a question about the Bantam e-STATION BC6 Dual Power and is the answer not in the manual?
Brand | Bantam |
---|---|
Model | e-STATION BC6 Dual Power |
Category | Battery Charger |
Language | English |
Auto-sets current, prevents over-charging, and ensures maximum safety during operation.
Operates with AC or DC input, supporting 5A capacity and 50 Watts charging power.
Built-in cell voltage balancer for Lithium batteries, negating the need for a separate unit.
Monitors and balances individual Lithium cells during discharge, stopping on abnormality.
Supports LiIo, LiPo, and LiFe batteries with different chemistry characteristics.
Offers 'Fast' charge for reduced time and 'Storage' mode for long-term battery preservation.
Includes Delta-peak sensitivity, auto-charge current limit, and capacity limit for safety.
Covers temperature limit, processing time limit, and input power monitoring for enhanced safety.
Store and recall up to 5 battery data profiles for quick setup and operation.
Perform 1-5 cycles of charge/discharge for battery refreshing and balancing.
Analyze battery performance using PC software via USB connection for detailed graphs.
Details the physical ports, screen, buttons, and connectors of the BC6 charger unit.
Avoid dust, damp, heat, vibration, drops, and keep away from flammables.
Do not use simultaneous AC/DC power; connect cables correctly to prevent shorts.
Ensure correct battery information and program setup to prevent damage or fire.
Lists battery types that should not be charged/discharged, including mixed types or non-rechargeable.
Verify program selection, current settings, connections, and battery pack composition before charging.
Explains energy transfer, connection, charge leads, connectors, and manufacturer instructions.
Emphasizes verifying Lithium battery capacity/voltage and avoiding parallel/series mixing.
For determining capacity or lowering voltage; set final discharge voltage correctly.
Explains memory effect in NiCd/NiMH and recommends cyclic conditioning for NiCd.
Lithium batteries prefer partial discharge; avoid frequent full discharges.
Visual guide to selecting battery types, charge/discharge modes, and advanced settings.
Select LiFe, LiIo, or LiPo voltage type to ensure correct charging.
Set time to verify Lithium cell count, default 10 min, to prevent errors.
Configure Delta-peak sensitivity for NiMH/NiCd charge termination.
Assign the 3-pin port to USB or Temperature sensor and set temperature cut-off.
Set a delay between charge/discharge cycles for battery cooling.
Configure an automatic safety timer to prevent overcharging if termination fails.
Set a maximum charge capacity limit for automatic process termination.
Enable or disable key beep and buzzer sounds for user feedback.
Set a minimum input voltage to protect the power source from damage.
Details constant voltage/current charging for LiIo, LiPo, LiFe batteries.
Select battery type, charge current, and voltage; confirm cell count before starting.
Shows current charge status including cells, time, voltage, current, and capacity.
Balances individual cell voltages by monitoring and controlling charge current.
Set current and voltage, confirm cell count for balance charging.
Displays status during balance charging, showing cells, time, voltage, current, capacity.
Pin assignment diagram for connecting individual cells for balancing.
Reduces charging time by modifying the CV process, potentially slightly reducing capacity.
Charges or discharges batteries to a specific voltage for long-term storage.
Set discharge current and final voltage, avoiding deep discharge for battery health.
Monitors individual cell voltages during storage/discharge, stops on abnormality.
Charge NiMH/NiCd batteries in 'Aut' or 'Man' mode, setting current limits.
Discharge NiMH/NiCd batteries by setting current and final voltage.
Perform charge-discharge or discharge-charge cycles for battery conditioning.
Displays status and results of each charge/discharge cycle.
Charge lead-acid batteries with specific current and voltage settings, avoiding rapid charging.
Discharge lead-acid batteries by setting current and final voltage.
Store up to 5 battery profiles with their settings for quick recall.
Set charge current, discharge voltage, and cycle settings for saving.
Recall previously saved battery data profiles to resume charging/discharging.
Choose a saved data number to load its associated battery parameters.
Display end voltage, capacity cut-off, safety timer, USB/Temp status, external temp, and input power.
Monitor individual cell voltages for Lithium battery packs connected via the individual port.
Lists common error messages and their explanations for system issues.
Covers polarity, connection breaks, shorts, input voltage, selection errors, and unit malfunctions.
Defines Amps (A), Milli-amps (mA), milli-amp hours (mAh), and amp-hours (Ah).
Explains Nominal Voltage (V) for different battery types and 'C'-rating for current limits.
Chart showing maximum charge/discharge currents for NiCd/NiMH, LiPo, Lilo, LiFe batteries by cell count.
Lists operating voltage, circuit power, current ranges, cell counts, weight, and dimensions.
Details the one-year warranty period, coverage, and exclusions for defects.
Provides contact information for BANTAM Inc., including address, phone, fax, and email.