61-101-00802.EF1 Revision J Page | 11
C. Connecting Test Set
(1) Connect T/S as per Figure 5 or Figure 6 and the following steps.
Note: Figure 5 depicts the use of Adapter cable P/N 101-00831 for conversion to
systems with circular style connectors.
(2) Connect T/S IND connector to Indicator.
(3) Connect T/S ACFT connector to aircraft wiring plug.
Figure 5 Indicator Test (With 101-00831 Adapter)
Figure 6 Indicator Test
D. Test
(1) Set the T/S ON / OFF switch to ON.
(2) Set the CAP SIM (pF) 100’s to 1. Set 10’s thumbwheels to 8.