Operation manual for Model 3K with Cone fire
RAMPCONEA 9-18-08
Add Temperature to Hold Period
Available only during a hold period This option allows you to
add temperature in 5 degree increments to a hold (soak) period. When in a hold period (during a
hold or soak, the temperature in the kiln will be alternating in the display with the remaining hold
time), press the UP key. When "SStP" is displayed press the UP key twice more and "tMP" will
be displayed. Press ENTER and 5 degrees will be added to the hold temperature. You may use
the add temperature procedure as many times as necessary to get the hold temperature that you
want.
Error Codes
tC FAIL tC alternating with FAIL indicates the thermocouple has failed. Replace the defective thermocouple. To clear the error, press
any key.
ErrP ErrP is displayed whenever there is a power interruption that is long enough to stop the firing. If the power interruption is brief the
kiln will continue to fire when power is restored; in this case there will no indication of a power failure. To clear the error, press
any key.
tC- - The red and yellow thermocouple wires are reversed.
Messages
CPLt Firing Cycle Complete (firing time is alternately displayed).
dELA Delay. Displays when entering the delay time (hour:minutes) until the start of the firing.
DLy Delay. Alternates with the remaining delay time until the start of the kiln.
F # Segment temperature in F Set temperature for a user program.
C # Segment temperature in C Set temperature for a user program. A decimal point will display in lower right corner.
EdIt Edit the default options (beeping at complete, temperature scale, cone fire, delay, maximum programmable temperature)
ErrP There has been a power interruption that has stopped the firing. Press any key to clear.
FULL Beeps continuously at end of firing until a key is pressed.
HLd# Soak time in hours:minutes at a hold temperature.
OFF No beeping when firing is complete.
On Beeps for 15 seconds at end of firing.
rA # Ramp Number (rate per hour of temperature increase or decrease).
rEdl Ready to fire current program. Press START to begin firing.
SEG Short for Segments. You can enter up to 8 segments in a program.
SStP Skip Step (used to advance to the next ramp)
StOP The kiln is at idle and ready to be programmed. Stop alternates with the current kiln temperature.
USr # User program number displayed