Possible Malfunctions
104304 23 / 30
Power supply
malfunction alarm
or no electric
supply
Check electric connections and
power supply
Disconnection of alarm signal:
– touch the control key once to
silence the buzzer
– touch the control key once to
silence the buzzer if it is the
first minute of operation
– only two touches of the control
key if the first minute has
elapsed
Clogged discharge
opening
Check the appliance for obstacles
in discharge route
Replace the discharge pump
Too long a
defrosting process
alarm
Defrosting process takes
too long
Check filling with coolant
Check electric power connection
Appliance continues
operation
Clean air filter and condenser
Inverted
evaporator–deposit
probe alarm
Check wiring on the sensor's
PCB; replace the sensor's PCB if
needed
The appliance stops, IR
probe damaged
Check probe connection to PCB
Replace the damaged probe