BE1-851E
9
5 Amp CURRENT INPUTS
Continuous: 20 Amps
One Sec. Rating: 400 Amps
Saturation limit: 150 Amps
Max. Burden: <10 milliohms
1 Amp CURRENT INPUTS
Continuous: 4 Amps
One Sec. rating: 80 Amps
Saturation limit: 30 Amps
Max. Burden: <22 milliohms
A/D CONVERTERS
Sampling Rate: 24/cycle
POWER SUPPLY
Option 1: DC Range 35-150 V
AC Range 55-135 V
Option 2: DC Range 90-300 V
AC Range 90-270 V
Option 3: DC Range 17-32 V (down to
8 V for momentary dips)
Burden: 6 W continuous, 8 W maximum
with all outputs energized
OUTPUT CONTACTS
Make and carry: 30 A (0.2 sec)
Continuous: 7 A
Break: 0.3 A DC (L/R=0.04)
@ 125 Vdc or 250 Vdc
CONTROL INPUTS
Wetting Voltage range: Same as control power
supply option.
Low Range High Range
Turn-on Turn-on
Power Supply Voltage Voltage
Option Range Burden Range Burden
1) 48/125 Vac/Vdc 26-38 Vac/dc 23k ohms 69-100 Vac/dc 53 k ohms
2) 125/250 Vac/Vdc 69-100 Vac/dc 66k ohms 138-200 Vac/dc 123 k ohms
3) 24 Vdc N/A N/A Approx. 5 Vdc 6 k ohms
Control inputs recognize both DC and AC voltages.
COMMUNICATION PORTS
Response Time: <100 mSec for metering and
control functions
Baud Rate: 300-19200
ELECTRICAL ENVIRONMENT
IEEE C37.90-1989 Standard for Relays and Relay
Systems Associated with Electric Power Apparatus
IEC 255-5 Insulation Test for Electrical Relays
Impulse and Dielectric Strength
(2000Vac at 50/60Hz)
IEEE C37.90.1-1989 Standard Surge Withstand
Capability Tests for Relays and Relay Systems
Associated with Electric Power Apparatus
IEC 255-22-1 1MHz Burst Disturbance Tests for
Electrical Disturbance Tests for Measuring Relays
and Protection Equipment
EN 61000-4-4 Electrical Fast Transient/Burst Immu-
nity Test
EN 61000-4-3 Radiated, Radio-frequency, Electro-
magnetic Field Immunity Test
Type tested using a 5-watt, hand-held transceiver in
the ranges of 144 and 440MHz with the antenna
placed within 6 inches of the relay.
IEEE C37.90.3 (Jan. 01) Draft Standard Electrostatic
Discharge Tests for Protective Relays
EN 61000-4-2 Electrostatic Discharge Immunity Test
MECHANICAL ENVIRONMENT
Operating temperature range: -40°C to 70°C*
(-40°F to 158°F)
*LCD Display is inoperative below -20°C.
Storage temperature range: -40°C to 70°C
(-40°F to 158°F)
Humidity: Qualified to IEC 68-2-38, 1st Edition 1974,
Basic Environmental Test Procedures,
Part 2: Test Z/AD: Composite Temperature Humidity
Cyclic Test
Vibration: 2g at 10 to 500Hz
Shock: 15g drop test
CERTIFICATIONS
cURus recognition per UL Standard 508, File
E97035 and CSA Standard C22.2 No. 14
CE Qualified - Meets or exceeds the standards
required for distribution to the European
Community.
GOST-R Certified per the relevant standards of
Gosstandart of Russia
DNP 3.0 IED Certified, Subset Level 2, 6/20
by SUBNET Solutions, Inc.
CASE SIZE
10.50" (266.7mm) W x 3.47" (88.1mm) H x
9.10" (231.1 mm) D with mounting flanges
(8.5" (215.9 mm) W without mounting flanges)
SHIPPING WEIGHT
Approx. 10 (4.536 kg) pounds
WARRANTY
7 years