Purification Systems
Page 63 3rd Edition, Rev 0 Chg 6
11. Close the bleed valve, restore the power and reconnect the inlet supply line, if applicable.
5.2.2.3 Cartridge Leaks after Installation
1. Remove the cartridge following steps to 3.3. in Paragraph 5.2.2.2.
2. Install cartridge if it is missing.
3. Remove cartridge with the T-wrench and inspect O-rings.
4. Replace O-rings if necessary.
5. Ensure protective caps and devices have all been removed.
6. Replace cartridge following steps 8. 7. to 11.11. in Paragraph 5.2.2.2.
Figure 5-3 Cartridge Replacement
NOTICE
If air is detected bleeding out from the bottom of the chamber, the cartridge has not been installed
properly or is missing. Follow the instructions in Paragraph 5.2.2.3.