MNL-0096
April 17, 2013 Page 36
4.6.6 P5S and IP5S Purification System
Item Qty Part No. Description Notes
1 1 079416 Oil and Water Separator See Figure 4-23
2 1 011430 Condensate Drain Valve
3 2 VAL-0007 Check Valves
4 1 080144 27” Dryer Chamber See Figure 4-28
5 1 080145 27” Securus
®
Chamber See Figure 4-30
6 1 VAL-0377 Bleed Valve
7 1 VAL-0053 Pressure Maintaining Valve
8 1 VAL-0169 Safety Valve
9 1 N15095 Securus
®
Indicator 110-120VAC, 50-60 Hz
1 N15096 Securus
®
Indicator 12-24 VDC
1 MNR-0042 Securus
©
Monitor
Figure 4-13 P5S and IP5S Purification System
OUT
IN
7
3
8
1
2
3
4
5
6
9
Securus
OUT
IN
7
3
8
1
2
3
4
5
6
9
Securus II

Table of Contents