Installation
Mono Power Unit BUM 62 T 45
Baumüller Nürnberg GmbH 5.99009.03
Plug-in terminal X99 AB
Screw connections for cable with wire crimp.
1. Position
2. Voltage range (r.m.s. value)
3. Current range (r.m.s. value)
4. Cross-section of the conductor
5. This message only refers to the BUM 62 T, and not to the controller!
(see also ”Messages via relay contacts” on page 61 )
Termina
l
Pos.
1)
Description
U
range
2)
I
range
3)
A
4)
1
Message "External ready for operation"
5)
Open contacts.
Supply part not ready
Closed contacts.
Supply part ready
24 V 0.5 A max.
2.5 mm
2
2
3
Message "Early warning"
5)
Closed contacts.
Supply part – no early warning
Open contacts.
Supply part – early warning
4
+Reset 5 isolated optocoupler input to
reset error messages.
PHASE ERR, POWER ERR, and BRAKE
OVERL.
24 V -
M Reset 6 Reference to input +Reset 0 V -