EasyManua.ls Logo

Baumuller BUM 62 T - Page 45

Baumuller BUM 62 T
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Mono Power Unit BUM 62 T 45
Baumüller Nürnberg GmbH 5.99009.03
Plug-in terminal X99 AB
Screw connections for cable with wire crimp.
1. Position
2. Voltage range (r.m.s. value)
3. Current range (r.m.s. value)
4. Cross-section of the conductor
5. This message only refers to the BUM 62 T, and not to the controller!
(see also ”Messages via relay contacts” on page 61 )
Termina
l
Pos.
1)
Description
U
range
2)
I
range
3)
A
4)
1
Message "External ready for operation"
5)
Open contacts.
Supply part not ready
Closed contacts.
Supply part ready
24 V 0.5 A max.
2.5 mm
2
2
3
Message "Early warning"
5)
Closed contacts.
Supply part – no early warning
Open contacts.
Supply part – early warning
4
+Reset 5 isolated optocoupler input to
reset error messages.
PHASE ERR, POWER ERR, and BRAKE
OVERL.
24 V -
M Reset 6 Reference to input +Reset 0 V -