APPLICATION RANGE
When using the generator, make sure the total load is within rated output
of a generator. Otherwise, generator damage may occur.
AC
Power
Factor
1 0.8-0.95 0.4-0.75
(Efficiency
0.85)
I3500L ~3,000W ~2,400W ~1,200W Rated
voltage 12V
Rated
current 8A
TIP:
• Application wattage indicates when each device is used by itself.
• The simultaneous usage of AC and DC power is possible but total
wattage should not exceed the rated output.
EX:
Generator rated output 3,000V A
Frequency Power factor
AC 1.0 ~3,000W
0.8 ~2,400W
DC --- 96W (12V/8A)
NOTICE
• Do not overload. The total load of all electrical appliances must not
exceed the supply range of the generator. Overloading will damage
the generator.
• When supplying precision equipment, electronic controllers, PCs,
electronic computers, microcomputer based equipment or battery
chargers, keep the generator a sufficient distance away to prevent
electrical interference from the engine. Also ensure that electrical
noise from the engine does not interfere with any other electrical
devices located near the generator.
• If the generator is to supply medical equipment, advice should first be
obtained from the manufacturer, a medical professional or hospital.
• Some electrical appliances or general-purpose electric motors have
high starting currents, and cannot therefore be used, even if they lie
within the supply ranges given in the above table. Consult the equip-
ment manufacturer for further advice.