TECHNICAL SPECIFICATIONS
Technology: microwave motion sensor
Radiated frequency: 24.125 GHz
Radiated power density: < 5 mW/cm
2
Supply voltage:
to be operated from SELV-compatible
power supplies only
12 – 24 VAC ±10%
12 – 24 VDC +30% / -10%
Supply frequency: 50 – 60 Hz
Power consumption: < 1.5W
Output
relay contact rating (max. voltage):
relay contact rating (max. current):
Max. switching power:
relay with switch-over contact (voltage-free)
60 VDC / 125 VAC
1A (resistive)
30W DC / 60 VAC
Detection range: 4 – 24” (adjustable)
Detection mode: motion (bidirectional)
Output hold time: 0.5 – 30 sec
Temperature range: -4 – 131 °F (-20 – 55 °C)
Weight: 0.34 lbs
Material: PC, PE
IP rating: IP54
Certification: Electromagnetic compatibility (EMC) according to 2004/108/EC
FCC: G9B-210161
IC: 4680A-210161
Specifications are subject to change without prior notice.
All values measured in specific conditions.
SINGLE-GANGJAMB DOUBLE-GANG 6” ROUND
Visit website for
available languages of
this document.
MOUNTING BOX COMPATIBILITY
JAMB SINGLE-GANG DOUBLE-GANG 6” ROUND
SURFACE-MOUNT 10BOXJAMBST
10BOX24SGSM
10ABOXSGSMS
10BOXDGSM
10BOX475SQSM (must
use adapter bracket)
10BOX6RNDSM (must
use adapter bracket)
FLUSH-MOUNT N/A
standard, single-gang
electrical box (not
provided by BEA)
standard, double-gang
electrical box (not
provided by BEA)
standard, single-gang
electrical box (not
provided by BEA)
Question and Answer IconNeed help?

Do you have a question about the BEA MS31 Series and is the answer not in the manual?

BEA MS31 Series Specifications

General IconGeneral
BrandBEA
ModelMS31 Series
CategorySwitch
LanguageEnglish

Summary

Technical Specifications

Product Performance Details

Details on technology, frequency, power, detection range, and operating conditions.

Safety and Installation Guidance

Precautions for Safe Operation

Essential safety measures to follow before and during installation and operation.

Installation Tips for Best Performance

Advice on wiring multiple devices and sensor placement for optimal functionality.

Setup and Installation Procedures

Sensor Adjustment Settings

Configuration of sensitivity, hold time, output mode, and LED mode.

Physical Installation Steps

Guidance on installing an electrical box and attaching the sensor assembly.

Troubleshooting and Compliance

Common Operational Issues and Solutions

Diagnosing and resolving problems like no power, incorrect detection, or door remaining open.

Regulatory Compliance and Approvals

Information on FCC/IC compliance and manufacturer's installation expectations.

Related product manuals