USER MANUAL FOR
BEAMEX
®
MC6 ADVANCED FIELD CALIBRATOR AND COMMUNICATOR
Applies to firmware version 1.70
Dear user,
We have made every effort to ensure the accuracy of the contents of this man-
ual. Should any errors be detected, we would greatly appreciate to receive sug-
gestions to improve the quality of the contents of this manual.
For more detailed technical data about Beamex
®
MC6 Advanced Field Calibra-
tor and Communicator, please contact the manufacturer.
8860000 / MC6uEng / Version 1.7
© Beamex 2012 - 2016
BEAMEX OY AB
Ristisuonraitti 10
FIN-68600 Pietarsaari
FINLAND
Tel +358 - 10 5505000
Fax +358 - 10 5505404
E-mail: sales@beamex.com
service@beamex.com
Internet: http://www.beamex.com

Table of Contents

Other manuals for BEAMEX MC6 Series

Questions and Answers

  • S
    Sarah FloresAug 11, 2025
    What to do if pressure is not rising in my MC6 family calibrator from BEAMEX Test Equipment?
    • J
      Jeffrey AllenAug 11, 2025
      If you don’t see the pressure rising in your MC6 family calibrator even though the pump is running, check your connections. Ensure that you are connected to the correct pressure module, specifically the one selected as the Reference Module in Controller Presets.
  • S
    Susan LoveAug 20, 2025
    Why does pressure generation stop, pressure vent, and the ePG switch off during BEAMEX Test Equipment calibration?
    • W
      William CarpenterAug 20, 2025
      If the pressure generation stops during calibration, the pressure is vented, and the ePG switches off, it is likely that the ePG battery has run out. To resolve this, recharge the ePG battery to continue your work.
  • D
    dunnjonathanAug 31, 2025
    What to do if pressure generation stops during BEAMEX Test Equipment calibration but pressure is not vented?
    • J
      Justin SharpAug 31, 2025
      If pressure generation stops during calibration, but the pressure isn't vented, ensure all cables are securely connected. The ePG will halt generation if the USB communication cable is removed.

BEAMEX MC6 Series Specifications

General IconGeneral
TypeMultifunction Calibrator
Measurement CapabilitiesVoltage, current, resistance, frequency, temperature, pressure
Calibration CapabilitiesPressure, Temperature, Electrical signals (Voltage, Current, Resistance, Frequency, Pulses)
DisplayColor touchscreen
PowerRechargeable battery
Operating Temperature-10 °C to +50 °C
Power SupplyBattery or external power
Enclosure RatingIP65