77English
from the local weather report. Please note that the data has to be
entered into the weather staon.
• Atmospheric pressure unit - The default seng in Europe is the
unit "hPa". Alternavely, you can set the unit "inHg".
8.1 Temperature alarm
You have the opon to dene a temperature range for the outdoor sensor. With
the temperature alarm, the base staon will emit an alarm sound if the outdoor
sensor measures anything outside this temperature range.
Press and hold the "ALERT" buon at the back of the base staon for about 3
seconds. The temperature display starts ashing. The following symbol starts
ashing " ".
Then press the "UP" or the "DOWN" buon to select the maximum temperature
of the desired range. Conrm the value by pressing the "ALERT" buon. The "
" symbol starts ashing in the temperature display. By pressing the "UP" and
"DOWN" buons, you can now select the minimum value of the desired tempera-
ture range. Conrm again by pressing the "ALERT" buon. The temperature alarm
is now ready for use.
Press the "ALERT" buon now to enable or disable the temperature alarm. If the
temperature alarm is enabled, the symbol " " appears in the display.
If the outdoor sensor measures a temperature outside the previously congured
range, an alarm is emied for about one minute from the base staon. This alarm
can be muted by pressing a corresponding buon on the weather staon. The
temperature which triggered the alarm will start ashing in the display. Press the
"ALERT" buon to switch the alarm o.