EasyManua.ls Logo

Bego LaserStar T Plus - Setting Combinations

Bego LaserStar T Plus
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
86076 DB-en/03 355.00032
English
LaserStar T Plus
en
Setting combinations
* If different alloys are welded together, always use the higher-quality filler metal.
All values indicated are only reference values and a basis for your own tests!
Feed argon correctly to the welding point!
Service Tel.: +49 421 2028-282 / -379
Situation
Voltage
V
Time
ms
Focal
point
Ø
Filler metal of
the same type
necessary?*
1 Clasp break partial denture (Co-Cr) 270 4,0 0,6
yes
Partial denture
2 Break in sublingual bar (PD) 280 4,0 0,4
3 Cavity in partial denture frame 280 4,0 0,7
4 Retentions (bent) to partial denture 270 6,0 0,7
5 Upper-jaw base extension 270 4,0 0,6
6 Precious-metal secondary crown to partial denture 290 9,0 0,6
7 Precious metal bar sleeve to partial denture 290 8,0 1,0
8 Anchor / attachment male parts to partial denture 300 8,0 1,2
9 Build up crown border (Precious metal) 270 3,0 1,0
yes
Precious metal
10 Defects in precious-metal crowns 280 4,0 1,2
11 Weld precious-metal bridge 290 10,0 0,4
12 Align precious-metal bridge 290 6,0 1,0 no
13 Build up contact points (precious metal) 290 4,0 1,2 yes
14
Precision pins for friction to telescopic crowns (pre-
cious metal)
280 4,0 1,2 no
15
Increase friction of secondary crowns (precious
metal)
260 2,5 1,0 no
16 Dolder bar to crown (precious metal) 270 2,5 1,0 yes
17 Build up crown border (non-precious) 240 5,0 0,4
yes
Non-precious
18 Fill cavities in non-precious crowns 270 5,0 0,5
19 Weld non-precious bridges 280 5,0 0,4
20 Align non-precious bridges 300 5,0 0,8 no
21 Weld palladium-base crowns together 290 7,5 0,6
yes
Pd
22 Partial denture to palladium-base crowns 280 6,5 0,6
23 Clasp break partial denture (titanium) 270 2,5 1,0 no
Titanium
24 Break lingual bar (titanium) 260 3,0 0,8 yes
25 Weld titanium bridge 300 3,5 1,0 no
26 Titanium: bar to implant 280 2,5 1,2 no
27 Titanium to precious metal 290 3,0 1,2 yes
28 Weld orthodontic wires 240 3,0 1,2 yes
KFO

Related product manuals