* The preset pulse shape is the standard pulse shape with the maximum possible energy. If a different
pulse shape is selected, the other parameters have to be adapted accordingly.
All values indicated are only reference values and a basis for your own tests!
Memory
location
Display
Application
Voltage
V
Duration
ms
Focus
Ø
Pulse
shape*
1
Clasp break PD
Clasp break in partial denture
270 4,0 0,6
2
Retentions to PD
Partial denture retentions to
partial denture
270 6,0 0,7
3
PA to PD
Precious-metal secondary
crown to partial denture
290 9,0 0,6
4
Weld PA bridge
Weld together
precious-metal bridge
290 10,0 0,4
5
cont. Point PA
Build up contact points
(precious metal)
290 4,0 1,2
6
Frict.sec.crown
Increase friction of secondary
crowns (precious metal)
260 2,5 1,0
7
Weld NP bridges
Weld together
non-precious bridges
280 4,0 0,4
8
PdPd base alloy
Between palladium base alloys
290 7,5 0,6
9
Weld bridge Ti
Weld titanium bridge
260 2,5 0,8
10
Weld Ni wire
Weld orthodontic wires
240 3,0 1,2