14 EXPANSION CARD X-DANTE
Note that the check boxes for ‘Slave to External Word Clock’ are
unchecked in this application.
Alternative Synchronization:
Use the internal X32 clock as master clock. In this case the
Setup/Cong page should look like this:
Note that the status bar shows “L 44K1” and a green light for Local
(internal) clock of 44.1 kHz.
The second green light “C: Dante” indicates proper installation of
the X-DANTE card.
The Dante Controller must now be congured for “Slave to
External Word Clock” in this application. See the X32 PRODUCER
line, which is congured Master in this example: