Safety Precautions
POTENTIELÉLECTROSTATIQUERISQUEDECHARGEMENT,
VOIRINSTRUCTIONS.
Warning:
Explosionhazard! Substitutionofcomponentsmayimpairsuitabilityfor
ClassI,Division2.
RISQUED'EXPLOSION!LASU BSTITUTIONDECOMPOSANTSPEUT
NUIREÀLACONFORMITÉDECLASSEI,DIVISION2.
• Use minimum 85°C copper conductors only.
• To make wiring connections to the power supply connector, follow the table
with cable and torque specifications below:
• ThesedevicesareClass2suppliesprogrammablecontrollers(industrialPCs)
or the use in industrial control equipment and are intended to be (front) panel
mounted.
• For use on a flat surface of a n enclosure.
TerminalBlockConnector WireSize Torque(Nm)
PhoenixContact 0.5–3.3mm
2
0.6–0.8
Caution:
Theeq uipmentshallbeinstalledinanenclo
surethatprovidesadegreeofprotection
notlessthanIP66inaccordancewithEN/IE
C60079-0whenusedinZone2/22
applications.
Theinsideoftheenclosurethedeviceis
mountedi nshallnotbemorethanpollution
degree2,asdefinedinE N/IEC60664-1.
CETÉQUIPEMENTESTTESTÉENTANT
QUECOM POS ANTETDOITÊTRE
INSTALLÉDANSUNBOÎTIERAVECI
NDICEDEPROTECTIONIP66MINIMUM.
Caution:
TemperaturecodeT4IEC/EN60079-0,IEC/EN60079-7,IEC/EN60079-15andIEC/
EN60079-31.
ProtectionstringExecnCIICT4GcandExtcIIICT82°CDc.
CODESDETEMPÉRATURET4IEC/EN60079-0,IEC/EN60079-7,IEC/EN60079-15et
IEC/EN60079-31.
CHAîNEDEPROTECTIONExecnCIICT4GcetE xtcIIICT82°CDc.
1.5 IECEx/ATEXCertificateandDust
Rating
II3GExecnCIICT4Gc
II3DExtcIIICT82°CDc
BeijerElectronics, MAEN249B
6