Configuration
Calibratetouchscreen Willinitializethecalibrationofthe
touch.
Thetouchcalibrationsc reenenables
thefunctiontorecalibratethetouch
screen. Therecalibrationconsistsof
ninesteps,whereacrosshaironthe
screenispressedandheld. Takecare
andtrytodothisaspreciseaspossible,
anincorrectcalibrationmakesithardto
usetheoperatorpanel.
Savebutton TheUR L,yorbrightnessandsceentime
out.
4.4 Network
The following parameters can be set:
• IP address
• Subnetmask
• Default gateway
• DNS settings for the Ethernet port on the operator panel
• LAN A / LAN B – One config per port (separate tabs in the top of the UI)
– Method – DHCP or Static.
– IP
– Netmask
– Gateway
– DNS 1
– DNS 2
– Save – Saves the new settings.
The default setting for LANAis: IP address 192.168.1.1, Subnet mask
255.255.255.0
4.5 Diagnostics
Displays a the following list of parameters for the panel:
• CPU load
• System uptime
• Memory total
• Memory usage
4.6 Licenses
Shows a full table of all the licenses used in the software in terms of
• Package
• Version
• License