EasyManua.ls Logo

Belden HIRSCHMANN BRS50 - Immunity; Electromagnetic Compatibility (EMC)

Belden HIRSCHMANN BRS50
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
Installation BRS20/22/30/32/40/42/50/52
Release
12
01/2022
7.10 Immunity
7.11 Electromagnetic compatibility (EMC)
Note: Use shielded data cables for gigabit transmission via copper cables. Use shielded data cables for all transmission
rates to meet the requirements according to EN 50121-4 and marine applications.
Immunity Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications Railway applications
(trackside) as per EN 50121-4
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 3.5 mm
(0.14 in) amplitude
2 Hz ... 13.2 Hz with 1 mm
(0.04 in) amplitude
8.4 Hz ... 200 Hz with 1 g 13.2 Hz ... 100 Hz
with 0.7 g
IEC 60068-2-27, test Ea Shock 15 g at 11 ms
Table 25: Immunity
EMC interference emission Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications Railway applications
(trackside) as per EN 50121-4
EN 55032 Class A
DNV Guidelines EMC B
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled Fulfilled
Table 26: EMC interference emission

Table of Contents

Related product manuals