800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
5
4
AFBUP
,
AFBUP-
S,
AFXUP
,
AFXUP-
S
On/Off, Sprin
g
Return, 24 to 240 VAC
Accessories
AV
8-2
5
S
haft extensio
n
IND
-
AFB
D
am
p
er
p
os
i
t
i
on
i
n
di
cator
K7-
2
Universal clamp for up to 1.05” dia jackshaft
s
KH-AF
B
C
r
a
nk
a
r
m
TF-
CC
U
S
C
onduit fittin
g
T
oo
l-
06
8
mm
a
n
d
1
0
mm wr
e
n
c
h
Z
G
-1
00
Universal mountin
g
bracke
t
Z
G
-1
01
Universal mountin
g
bracke
t
Z
G
-11
8
Mountin
g
bracket for Barber Colma
n
®
MA 3../4.., Honeywel
l
®
M
od
III
o
r IV
o
r
Jo
hn
son
®
Series 100 re
p
lacement or new crank
arm t
yp
e installation
s
Z
G
-AF
B
C
rank arm adaptor kit
Z
G
-AFB11
8
C
rank arm adaptor kit
ZS-100 Weather shield (metal)
Z
S
-150 Weather shield
(
polycarbonate
)
ZS-260 Explosion-proof housin
g
Z
S
-
300
NEMA
4
X
h
ous
i
n
g
No
te
:
When using AFBUP, AFBUP-S, AFXUP, AFXUP-S actuators, only use accessories listed on
t
hi
s pa
g
e
.
For actuator wiring information and diagrams, refer to Belimo Wiring Guide
.
Typical Specification
On/Off sprin
g
return damper actuators shall be direct coupled type which require
n
o crank arm and linkage and be capable o
f
direct mounting to a jacksha
f
t up to a
1
.05” diameter. The actuators must be designed so that they may be used
f
or either
clockwise or counterclockwise fail-safe o
p
eration. Actuators shall be
p
rotected
from overload at all an
g
les of rotation. If required, two SPDT auxiliary switch shall
b
e provided havin
g
the capability of one bein
g
ad
j
ustable. Actuators with auxiliary
switches must be constructed to meet the requirements for Double Insulation so
an electrical
g
round is not required to meet a
g
ency listin
g
s. Actuators shall be
cULus a
pp
roved and have a 5
y
ear warrant
y
, and be manufactured under ISO 9001
I
nternational Qualit
y
Control Standards. Actuators shall be as manufactured b
y
B
elimo.
Wiring Diagrams
1
Provide overload protection and disconnect as required
.
2
C
A
U
TI
ON
E
qu
i
pment
D
amage
!
A
ctuators may be connected in parallel.
P
ower consum
p
t
i
on an
d
i
n
p
ut
i
m
p
e
d
ance must
b
e o
b
serve
d
.
3
No
g
round connection is required
.
4
For end
p
osition indication, interlock control, fan startu
p
, etc.
,
A
FBUP-
S
and AFXUP-
S
incorporates two built-in auxiliary switches: 2 x
S
PDT, 3A (0.5A)
@
250 VA
C
, UL Approved, one switch is fi xed at +10°, one
i
s a
dj
usta
bl
e 10° to 90°
.
Meets cULus requirements without the need of an electrical
g
round con
-
n
ec
ti
o
n.
WARNING
Live Electrical Components!
G
Durin
g
installation, testin
g
, servicin
g
and troubleshootin
g
of this product, it may be
necessar
y
to work with live electrical com
p
onents. Have a
q
ualifi ed licensed electrician or other
individual who has been properly trained in handlin
g
live electrical components perform these
tasks. Failure to
f
ollow all electrical sa
f
et
y
p
recautions when ex
p
osed to live electrical com
p
o
-
nents could result in death or serious injury.
AFBUP, AFBUP-S
AFXUP, AFBUP-S
W
066_AFB
(
X
)
UP
O
n
/Off
wiring
f
or AFBUP, AFXU
P
Wht
Blk
AFBUP-S
AFXUP-S
W
067_AFB
(
X
)
UP-
S
Auxiliary Switches for AFBUP-S, AFXUP-
S
N40103 - 09
/
11 -
S
ub
j
ect to chan
g
e.
©
Belimo Aircontrols
(
U
S
A
)
, Inc.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Belimo AFB Series and is the answer not in the manual?

Belimo AFB Series Specifications

General IconGeneral
BrandBelimo
ModelAFB Series
CategoryController
LanguageEnglish

Related product manuals