18
ERROR MESSAGES 
The control unit checks the correct operation of the safety devices. In the event of faults the following messages can be 
displayed:
ERR  Error, stroke self-learning or remote control code memorisationi.
ERR1  Error, PHOTOTEST PHOT O.
ERR2  Error, PHOTOTEST PHOT C.
ERR3  Error, Encoder.
EXAMPLE OF PROGRAMMING
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s 
- activate pre-blinking 
Perform the operations described below step by step:
Step Press Display Notes
1
PAR
First menu
2
TCA
First function of the first menu
3
040
Value currently set for the function selected
4
100
Set the desired value with the <+> and <-> keys
5
PRG
The value is programmed
TCA
When programming has been made, the display goes to the function just set
6
PAR
Press <+> and <-> simultaneously to go to the higher menu 
7
Log
Second menu
8
TCA
First function of the second menu
9
Pre
Press <-> several times to select PRE logic 
10
OFF
Value currently set for the function selected
11
ON
Set the desired value with the <+> and <-> keys
12
PRG
The value is programmed
Pre
When programming has been made, the display goes to the function just set
13
PAR
Press <+> and <-> simultaneously to go to the higher menu and quit programming or 
wait 30s.