9.8) ACCESS PASSWORD (CODE)
It allows you to enter the access protection code to control unit programming.
You can enter an alphanumerical code of four characters using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and indicates the absence of the protection code.
At any time, you can cancel the code entering operation, pressing the + and - keys simultaneously. Once the password is entered, you can operate
the control unit, entering and exiting programming for a time of approx. 10 minutes, to allow the adjustment and test operations of the functions.
By replacing the code 0000 with any other code, you enable protection of the control unit, preventing access to all the menus. If you want to enter a
protection code, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is displayed, also if the protection code was already entered.
- use the + and - keys to change the value of the flashing indicator light character.
- with the OK key, the character is confirmed and you move on to the next.
- after entering the 4 characters, a “CONF” confirmation message appears.
- after a few seconds, the code 0000 is displayed again.
- the protection code must be confirmed which was previously entered, to avoid involuntary entry.
If the code corresponds to the previous one, the “OK” confirmation message is displayed.
The control unit automatically exits the programming phase and to access the menu again, the saved protection code will be necessary.
IMPORTANT: NOTE the protection code and KEEP IT IN A SAFE PLACE for future maintenance. To remove a code from a protected control
unit, you should enter programming with the password and bring the code to the default value 0000.
IF THE CODE IS LOST, CONTACT AUTHORISED TECHNICAL SUPPORT, FOR TOTAL RESET OF THE CONTROL UNIT.
10) ERROR MESSAGES
The list is displayed of some messages which are shown on the display in the event of an operating anomaly:
Err1
motor error check motor connections
Err2
photocell error check connections, alignment of the photocells or obstacles present.
Err8
activation error on inputs during autoset
repeat autoset procedure.
Esvc
closure limit switch adjustment error repeat autoset procedure.
Esvo
opening limit switch adjustment error repeat autoset procedure.
ovld
motor overcurrent error
thrm
motor thermal error
Enc
encoder error check encoder connection/operation
Amp
motor obstacle error check the presence of obstacles or friction points on the stroke of the motor door
bar
activation of the sensor input during manoeuvre
check connections of the sensor and/or presence of obstacles on the stroke of the motor
door
11) DIAGNOSTICS
During normal operation, the LCD display shows the status of the inputs and outputs as in the dia-
gram alongside. Each activation of an input/output corresponds to switch-on of the relevant LCD
display segment.
SWC
STOP
SWO
PHOT
BAR
P.P. OPEN CLOSE