10
Dip-Switch functions
DIP 1 “TCA” The automatic closure is enabled or disabled
Off: disabled automatic closure
On: enabled automatic closure
DIP 2 “Prelam.” Forewarning flashing light enabled or disabled
Off: disabled forewarning flashing light
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
DIP 3 “Rall.” Braking is enabled or disabled.
Off: disabled braking, the “SWO” opening limit switch stops the motor immediately. The “SWC” closure limit
switch delays the motor stop by 1.5s in order to allow a better closure of the door.
On: Braking in both opening and closing phases.
N.B.: the braking phase starts when the limit switches are triggered.
DIP 4 “P.P. Mod” The operating mode of “P.P. Push button” and of the transmitter are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
DIP 5 “PHOT. AP.” The photocells in the opening phase are enabled or disabled.
Off: enabled photocells in the opening phase.
On: disabled photocells in the opening phase.
DIP 6 “Cond.” The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter have no
effect in the opening phase.
DIP 7 “VRall” Motor speed selection in the braking phase
Off: Minimum braking speed .
On: Maximum braking speed .
DIP 8 “TRall” This selects the braking phase time in seconds, in both opening and closing phases.
Off: 3 seconds.
On: 7 seconds.
LED Diagnostics
The control system has a series of self-diagnostics LED’s which allow to check all functions:
SW1 LED It switches on when the SWO opening limit switch is triggered
SW2 LED It switches on when the SWC closing limit switch is triggered
STOP LED It switches off when the STOP push button is pressed
PHOT LED It switches off when the photocells are not aligned or if obstacles are present
OPN LED It switches on when the OPEN push button is pressed
CLS LED It switches on when the CLOSE push button is pressed
PP LED It switches on when the PP push button is pressed