(3) Procedure:
Confirmed sample with
appearance and function ready
before testing then compare with
after test record as brightness,
uniformity and contrast ratio.
Perform random vibration after
sine-wave vibration test.
(2) Unpackaged Vibration
Unpackaged,
Non-
Operating
Test Spectrum:
20 Hz 0.0185(g2/Hz)
200Hz 0.0185(g2/Hz)
Duration : 5 Minutes
Axis : 3 axis ( Horizontal and
Vertical axis ,Z axis)
(3) Drop
Package,
Non-
Operating
91 cm Height (MP stage)
(1 corner, 3 edges, 6 faces)
(4) Shock
Wooden
package, Non-
Operating
Waveform: half sine
Faces: 6 sides/ per orientation
3 shocks.
Duration: <3ms
Velocity accelerate: 75g
3.1.7.12 Electrostatic Discharge Requirements
Item
Condition
Spec
OK
N.
A
Remark
Electrostatic Discharge
IEC801-2 standard
Contact: 8KV
Air: 15KV
3.1.7.13 EMC
Item
Condition
Spec
OK
N.
A
Remark
TCO03
Electric
Band 1 < 10 V/m
Band 2 < 1 V/m
Magnetic
Band 1 < 200nT
Band 2 < 25nT
EMI
FCC part 15J class B
After Mass production
under 1dBuv for constant
measure. Besides DNSF
and VCCI class-2 are
optional.
EN55022 class B

Other manuals for BenQ GL2055