43 Maintenance
14. Replace the lamp cover on the projector.
15. Tighten the screw that secures the lamp cover.
16. .Connect the power and restart the projector.
Resetting the lamp timer
17. After the startup logo, open the On-Screen Display
(OSD) menu. Go to Advanced menu - System > Light Source Information and press OK.
The Light Source Information page appears. Highlight Reset Light Timer and press OK. A
warning message is displayed asking if you want to reset the lamp timer. Highlight Reset and press
OK. The lamp time will be reset to “0”.
• Loose screw may cause a bad connection, which could
result in malfunction.
• Do not over tighten the screw.
Do not reset if the lamp is not new or replaced as this could cause damage.