EasyManua.ls Logo

Beretta EXCLUSIVE User Manual

Beretta EXCLUSIVE
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
EXCLUSIVE
C.A.I.
R.A.I.
MIX C.S.I.
MIX R.S.I.
EN INSTALLER AND USER MANUAL
ES MANUAL DE INSTALACIÓN Y USO
PT MANUAL PARA INSTALAÇÃO E USO
FR MANUEL D’INSTALLATION ET D’UTILISATION
HU TELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKÖNYV
RO MANUAL DE INSTALARE SI UTILIZARE

Questions and Answers:

Beretta EXCLUSIVE Specifications

General IconGeneral
BrandBeretta
ModelEXCLUSIVE
CategoryBoiler
LanguageEnglish

Summary

Manual Structure and Symbols

Manual Content Overview

Lists key sections like User's Manual, boiler elements, circuits, and diagrams.

Key Symbols in the Manual

Explains symbols used for warnings, prohibitions, and important notes.

General Safety Devices

Safe Handling and Manual Integrity

Covers care, wiring, and the manual's role as an integral part of the product.

Installation and Servicing Requirements

Details requirements for qualified personnel, annual servicing, and installer instructions.

Manufacturer Liability and Usage Restrictions

Outlines manufacturer liability, appliance purpose, and packaging handling.

Safety Precautions and Fault Handling

Covers safety valve, modifications, fault handling, user info, shutdown, and general measures.

Boiler Installation

Available Boiler Models and Types

Lists the different boiler models and their types (e.g., Combined, CH only).

Installation Location and Restrictions

Specifies where the boiler can or cannot be installed.

General Installation Guidelines

Provides guidelines on minimum spaces, insulation, and flammable substances.

Hydraulic Connections

Hydraulic Connection Points and Specifications

Details CH/DHW connection points, dimensions, and associated specifications.

Water Hardness and Softener Use

Recommends using softeners for hard water to prevent limestone deposits.

Gas Connection

Gas Connection Requirements and Checks

Ensures compliance with regulations, correct gas type, and pipe cleanliness.

External Gas Piping and Filtering

Covers wall passage for pipes and recommendations for using a filter.

Electric Connection

Accessing Electrical Terminals

Provides steps to access the unit's electrical terminals for connection.

Power Supply, Earthing, and Cable Specs

Details mains power supply, earthing requirements, and power cable specifications.

System Filling and Emptying

Filling the Central Heating System

Step-by-step guide for filling the system and achieving correct pressure.

Emptying DHW and CH Systems

Procedures for emptying domestic hot water and central heating circuits.

Safety Valve Outlet Connection

Instructions for connecting the safety valve outlet to a collection system.

Fumes Exhaustion and Air Suction (C.A.I. - R.A.I.)

Fume Exhaustion Configurations and Regulations

Details various configurations (C12-C82x) and general rules for fume extraction.

Concentric Outlet Installation (Ø 60-100)

Installation guidelines, graphs, and condensate collector requirements for Ø 60-100 outlets.

Concentric Outlet Installation (Ø 80-125)

Guidelines, table, condensate trap, and slope requirements for Ø 80-125 outlets.

Fumes Exhaustion and Air Suction (MIX C.S.I. - MIX R.S.I.)

Twin Outlet Installation (Ø 80)

Installation guidelines, tables, and condensate requirements for twin outlets.

Twin Duct Length and Bend Calculations

Information on maximum duct lengths and pressure drop for bends.

Technical Data

Heating and DHW Capacity Specifications

Details nominal and reduced heating and domestic hot water capacities.

Efficiency, Electrical, and Protection Data

Covers working efficiency, electrical power consumption, and protection levels.

CH and DHW Operation Parameters

Provides data on pressure, temperature, pump, and tank specifications for CH/DHW.

Gas and Hydraulic Connection Data

Specifies gas pressure, connection types, and pipe sizes.

Dimensions, Weight, and Fan Performance

Lists physical dimensions, weight, and fan head performance data.

Fume Exhaustion Pipe and Emission Data

Details fume pipe diameters, lengths, and emission values (NOx, CO).

Multigas Technical Data

Gas Properties and Supply Pressures

Details Wobbe index, heat value, and nominal/minimum gas supply pressures.

24 kW and 28 kW Gas Performance

Specifies gas capacities and pressures for 24 kW and 28 kW models.

26 kW, 30 kW, and 35 kW Gas Performance

Specifies gas capacities and pressures for 26 kW, 30 kW, and 35 kW models.

Start-Up and Operation (C.A.I. - MIX C.S.I.)

Control Panel Overview and Commands

Describes the control panel layout, buttons, and their functions.

Display Symbols Explained

Explains the various icons and symbols displayed on the boiler's control panel.

Operation Adjustments (C.A.I. - MIX C.S.I.)

Switching On the Boiler

Guides through the initial power-up sequence and test procedure.

Adjusting Heating Water Temperature

Details how to set heating water temperature manually or via an external sensor.

Adjusting Domestic Hot Water Temperature

Explains how to set the domestic hot water temperature.

Boiler Operation and Shutdown (C.A.I. - MIX C.S.I.)

Working the Boiler and Safety Stop

Describes normal boiler operation, safety stops, and fault code display.

Switching Off for Short Periods

Procedure for temporary shutdown, including anti-freeze and anti-block systems.

Switching Off for Long Periods

Instructions for shutting down the boiler for extended periods.

Boiler Functions: Semi-Automatic Filling

Details the semi-automatic filling device and its operation.

Advanced Functions and Troubleshooting (C.A.I. - MIX C.S.I.)

S.A.R.A. and DHW Preheating Functions

Explains the S.A.R.A. Booster and Domestic Hot Water Preheating functions.

S.A.R.A. Function Operation

Details how the S.A.R.A. self-adjustment system operates for comfort and energy saving.

Troubleshooting Fault Codes

Provides a table listing fault codes, alarm status, and corresponding symbols.

Programming Parameters

Resetting Faults

Step-by-step guide for clearing detected faults and resuming operation.

Parameter Programming Overview

Instructions on how to enter the parameter programming mode.

Setting the Access Password

Procedure for setting or entering the password to access parameter modifications.

Modifying Parameters

Guides on how to select, modify, and confirm parameter values.

Programmable Parameters (C.A.I.)

Gas Type, Insulation, and DHW/CH Modes

Parameters related to gas type, building insulation, and DHW/CH operating modes.

Heating Power, Timer, and Reset Functions

Parameters for heating power reduction, timers, and reset functions.

DHW Thermostat, Preheating, and S.A.R.A. Functions

Parameters for DHW thermostat, preheating, S.A.R.A., and thermoregulation.

Antifreeze and Filling Parameters

Parameters for antifreeze function temperatures and filling settings.

Start-Up and Operation (R.A.I. - MIX R.S.I.)

Operating Modes: Case A, B, and C

Explains the three operating cases for R.A.I./MIX R.S.I. boilers.

Control Panel Overview and Commands

Describes the control panel layout, buttons, and their functions for R.A.I./MIX R.S.I.

Display Symbols Explained

Explains the various icons and symbols for R.A.I./MIX R.S.I. boilers.

Operation Adjustments (R.A.I. - MIX R.S.I.)

Switching On the Boiler

Guides through the initial power-up sequence and test procedure for R.A.I./MIX R.S.I.

Adjusting Heating Water Temperature

Details setting heating water temperature manually or via an external sensor.

Adjusting Domestic Hot Water Temperature

Explains how to set domestic hot water temperature for specific cases.

Boiler Operation and System Filling (R.A.I. - MIX R.S.I.)

Working the Boiler and Safety Stop

Describes normal operation, safety stops, and fault code display for R.A.I./MIX R.S.I.

Switching Off for Short/Long Periods

Instructions for temporary and prolonged shutdown procedures.

Boiler Functions: Filling the Circuit

Details the procedure for filling the heating circuit and restoring pressure.

Related product manuals