12
MYNUTE X
Menu Parameter Value
Level
password
Value set
in the factory
Personalised
values
OTD CURVES
1.0-3.0
AT
0.2-0,8
BT
INSTALLER 2.0
NIGHT COMP 0 / 1 INSTALLER 0
POR 0 / 1 INSTALLER 0
MAN AUTO 0 / 1 INSTALLER 0
ZONE1 ENABLE 0 / 1 INSTALLER 0
ZONE1 ADDR 1 - 6 INSTALLER 1
ZONE1 HYDRAULIC CONFIG 0 / 1 INSTALLER 0
ZONE1 TYPE 0 / 1 INSTALLER 0
ZONE1 SET
ZONE1 MIN CH SET -
ZONE1 MAX CH SET
USER 40 - 80.5
ZONE1 MAX CH SET
AT: ZONE1 MIN CH SET - 80.5
BT: MIN CH SET - 45.0
INSTALLER 80.5
ZONE1 MIN CH SET
AT: 40 - ZONE1 MAX CH SET
BT: 20 - ZONE1 MAX CH SET
INSTALLER 40
ZONE1 OTR 0 / 1 INSTALLER 0
ZONE 1 OTD CURVES
1.0-3.0
AT
0.2-0.8
BT
INSTALLER 2.0
ZONE1 NIGHT COMP 0 / 1 INSTALLER 0
DHW
ANTILEGIO
NOT AVAILABLE ON THIS
MODEL
ANTILEGIO TIME
NOT AVAILABLE ON THIS
MODEL
ANTILEGIO TANK FLOW
NOT AVAILABLE ON THIS
MODEL
TANK HYSTERESIS ON
NOT AVAILABLE ON THIS
MODEL
TANK HYSTERESIS OFF
NOT AVAILABLE ON THIS
MODEL
TANK FLOW TEMP
NOT AVAILABLE ON THIS
MODEL
SLIDING TANK FLOW TEMP
NOT AVAILABLE ON THIS
MODEL
MIN DHW SET
NOT AVAILABLE ON THIS
MODEL 37.5
MAX DHW SET
NOT AVAILABLE ON THIS
MODEL 60
DHW DELAY 0 - 60sec SERVICE 0
SUN ON 0 / 1 / 2 / 3 / 4 INSTALLER 0
3WAY CONFIG
NOT AVAILABLE ON THIS
MODEL
TANK PUMP PWM
NOT AVAILABLE ON THIS
MODEL
RSI
POSTCIRCULATION
TIME
NOT AVAILABLE ON THIS
MODEL
SOLAR
FSUN 0 / 1 INSTALLER 0
T MAX TANK 10 130 INSTALLER 60°C
DELTA T ON PUMP DELTA T OFF PUMP 30°C INSTALLER 8°C
DELTA T OFF PUMP 4°C DELTA T ON PUMP INSTALLER 4°C
INTEGRATION DELAY
0-199 min INSTALLER 0min
COLLECTOR T MIN (--)/-30°C - 0 INSTALLER (--)
COLLECTOR T MAX COLLECTOR T PROT 180°C INSTALLER 110°C
COLLECTOR T PROT 80°C - COLLECTOR T MAX INSTALLER 110°C
COLLECTOR T AUTH COLLECTOR T LOCK - 95°C INSTALLER 40°C
COLLECTOR T LOCK -20°C - COLLECTOR T AUTH INSTALLER 35°C
PWM COLL PUMP 0min - 30min INSTALLER 0min
TANK COOLING 0 / 1 INSTALLER 0
SOLAR PUMP MODE 0 / 1 / 2 INSTALLER 0
SERVICE
TYPECOS
NOT AVAILABLE ON THIS
MODEL
EXPIRE
NOT AVAILABLE ON THIS
MODEL