SETTINGS MENU TREE STRUCTURE
Below is a list of the parameters that can be programmed; if the adjustment board does not support the relative function, the interface returns an error message:
The remote control has the function of a machine interface, displaying the system settings and providing access to the parameters.
The display normally shows the temperature of the ow sensor unless there is a domestic hot water request in progress, then the domestic hot water probe temperature is displayed; if no
key is touched within 10 sec the current time is displayed (backlight unlit).
The conguration MENU is organised with a multi-level tree structure. An access level has been xed for each sub-menu: USER level always available; TECHNICAL level password
protected.
Below is a summary of the SETTINGS MENU tree structure.
Some of the information might not be available depending on the access level, the status of the machine or the system conguration.
Menu Parameter Value
Level
password
Value set
in the factory
Personalised
values
SETTINGS
TIME USER
TIME PROGRAMM USER
COMB
GAS TYPE 0 / 1 INSTALLER 0
BOYLER TYPE 1 / 2 / 3 / 4 SERVICE
1 (25 kW)
2 (30 kW)
3 (35 kW)
4 (40 kW)
COMBUSTION OFFSET 0 / 1 / 2 SERVICE
CONF
HYDRAULIC
CONFIGURATION
0 / 1 / 2 / 3 / 4 INSTALLER 1
WATER TRANSDUCER 0 / 1 SERVICE 1
AUTO WATER FILL ENABLE 0 / 1 SERVICE 0
BEGIN SYSTEM FILLING NOT AVAILABLE ON THIS MODEL
AIR PURGING CYCLE 0 / 1 SERVICE 1
MIN INSTALLER
see technical data
table
MAX INSTALLER
see technical data
table
MAX_CH MIN - MAX INSTALLER
see technical data
table
RANGE RATED MIN - MAX_CH INSTALLER
see technical data
table
DO_AUX1 0 / 1 / 2 INSTALLER 0
EXHAUST PROBE RESET 0 / 1 INSTALLER 0
CH
HYST ON HIGH TEMP
2 - 10 SERVICE 5
HYST OFF HIGH TEMP
2 - 10 SERVICE 5
HYST ON LOW TEMP
2 - 10 SERVICE 3
HYST OFF LOW TEMP
2 - 10 SERVICE 3
PUMP CONTROL TYPE 0 - 100 INSTALLER 85
CH POSTCIRC
NOT AVAILABLE ON THIS
MODEL
LOW NOISE
NOT AVAILABLE ON THIS
MODEL
SCREED HEATING 0 / 1 INSTALLER 0
ANTI CYCLE FUNCTION 0 - 20min INSTALLER 3min
RESET CH TIMERS 0 / 1 INSTALLER 0
MAIN ZONE ACTUATION TYPE 0 / 1 INSTALLER 0
MAIN ZONE ADDR 1 - 6 INSTALLER 3
MAIN ZONE HYDRAULIC CONF 0 / 1 INSTALLER 0
MAIN ZONE TYPE 0 / 1 INSTALLER 0
MAX CH SET
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
INSTALLER
80.5
MIN CH SET
AT: 20 - MAX CH SET
BT: 20 - MAX CH SET
INSTALLER 20
OTR 0 (default) / 1 INSTALLER 0