30
Press first, then press
to check/adjust the User parameter from P0 to P7
If needed, press second, then press or to adjust the current parameter.
(for example: Press first, then press to enter parameter P7 checking, and press second, then
press or to adjust the parameter P7 Inlet water temp. Correction from -9 to 9.)
Code
Name
Scope
Defaul
Remark
P0
Mandatory
defrosting
0-1
0
0: Default normal operation
P1
Working mode
0-1
1
1:Heating mode, 0:cooling mode,
P2
Timer on/off
0-1
0
1 Timer on/off is under function
0 Timer on/off is out of
function (The setting of P5 and P6 won’t work)
P3
Water pump
0-1
0
1:Always running;
P4
Current time
HH:M
M
0000
0-23:0-59
P5
Timer on
HH:M
M
0000
0-23:0-59
P6
Timer off
HH:M
M
0000
0-23:0-59
P7
Water temp.
calibration
-99
0
Default setting: 0
NOTE: Under defrosting mode, P0=1. After defrosting finished, it will be automatic enter Normal
mode, P0=0.
7.4.4 System reset function
Press and in 10s, the system will reset and display 0000” on the controller.
7.4.5
Symbol of heating, the light will be on when it is in operation.
When defrosting, the light will flash.
7.4.6
Symbol of cooling, the light will be on when it is in operation.
Note: When parameter P1 is on checking/adjusting, and will be flashing at the same time.