32
7.5 Heating operation logic
Working status
Working mode
Water in
temperature-T1
For example,
water in
temperature-T1
Heat pump working level
1
Start-up
of
heat
pump
When you
select the
"Smart
working mode "
T1< Tset-1
T1< 27
Powerful mode-frequency F9
2
Tset-1T1 < Tset
27℃≦T1 <28
FrequencyF9 -F8-F7,...,-F2
3
Tset T1 <Tset+ 1
28℃≦ T1 <29
Silent mode-frequency F2
4
T1Tset+1
T129
HP will be in Standby, stop
working until the water
temperature drops to less
28.
5
When you
select
the "Silent
working mode".
T1< Tset
T1< 28
Smart mode -frequency F5.
6
TsetT1 < Tset+1
28℃≦T1 < 29
Silent mode-frequency
F2/F1.
7
T1Tset+1
T129
HP will be in Standby, stop
working until the water
temperature drops to less
28.
8
When you
select
the "Powerful
working mode."
T1<Tset+1
T1<29
Powerful mode-frequency
F10/F9
9
T1 Tset+1
T129
HP will be in Standby, stop
working until the water
temperature drops to less
28.
10
Re-start to
heat
water in
standby
status
When HP is
working at "
Smart mode"
T1Tset
T128
Standby
11
TsetT1Tset-1
28℃>T127
Silent-frequency F2
12
Tset-1
T1Tset-2
27℃>T126
Frequency F2
-F3-F4,...,-F9
13
<Tset-2
<26
Powerful-frequency F9
14
When HP is
working at "
Silent mode"
Tset
28
Standby
15
TsetT1Tset-1
28℃>T127
Silent mode-frequency F2/F1
16
T1<Tset-1
T1<27
Smart -frequency F5
17
When HP is
working at "
Powerful
mode"
T1<Tset-1
T1<27
Powerful -frequency F10/F9