en- 27
*depending on the equiment variant
13 First aid in the event of a fault
NOTE
Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault Possible cause Remedy
Reduction in suction Filter contaminated Clean.
eece lter full Change.
Container full Empty.
Nozzle, pipes or hose blocked Clean.
Vacuum cleaner will not start Mains plug plugged in?
Mains power missing?
Mains cable OK?
Cover closed properly?
Water sensor switched off?
Vacuum cleaner in readiness for
operation "AR"?
Set to "I" or "IR" (see "2 Display and Operating
Elements").
The vacuum cleaner does not start
when the tool is switched on in the
>AR< mode
Is the mains plug of the unit in the plug
socket?
Put the mains plug in the vacuum cleaner plug
socket
Solenoid valve of compressed air auto
-
matic switch-on* contaminated?
Flush the compressed air automatic switch-on* with
alcohol
PE
emptying and disposal bag is sucked
against the lter
Position of rotary slider incorrect Set rotary slider to OPEN (see "8.4 Inserting PE
emptying and disposal bag").
Vacuum cleaner classes M or H: with
inserted paper lter dust in lter
Position of rotary slider incorrect Set rotary slider to CLOSE (see "8.3 Inserting eece
lter bag").
Do not take any other action and contact the central customer service workshop.
14 Genuine accessories
NOTE
Use genuine accessories.
Article designation Properties/material Order quantity (1 set)
eece lter bag FBV 25/35 for 30 litre plastic container, BGIA class M approved 5/10 Number
Filter cassette FK 4300 Cellulose material, BGIA class M approved 2 Number
Filter cassette FKP 4300 Polyester material, BGIA class M approved 2 Number
Filter cassette FKP 4300 HEPA (H 14) 3 layer lter cassette, BGIA class H approved 2 Number
PE emptying and disposal bag only for IS vacuum cleaners class M and H 5 Pieces
PE emptying and disposal bag ASBESTOS only for IS vacuum cleaner H
ASBESTOS
5 Pieces
PE emptying and disposal bag ASBESTOS Only for ISP vacuum cleaners class H ASBESTOS 5 pieces